background image

9

Part No. 001132, 18-m09-2019

Orion MRL Owner’s Manual

3. OPERATING FROM THE LANDING CONTROLS

When using the landing controls, the cab can only be moved 
(called) to the level from which you are calling. When using the 
COP buttons in the cab, the cab can be moved to any level.

To call the elevator to the appropriate level:

1

Press the

 CALL 

button. The cab will automatically stop at your landing. 

2

When the elevator reaches the landing, the sliding doors will open 
automatically. Enter the cab. The doors will close behind you after a few 
seconds. Once inside the cab, lock the wheelchair wheels.

Wheelchair wheels must be locked at all times when the 
elevator is moving.

4. OPERATING FROM THE COP CONTROLS

1

If sitting in the cab in a wheelchair, lock the wheelchair wheels. If standing 
in the cab, hold on to the handrail.

2

Press the appropriate landing button to “send” the cab to the desired 
landing. 

3

When the elevator reaches the landing, the door will “chime” and the sliding 
doors will open automatically. Exit the cab. The doors will close behind you 
after a few seconds.

Wheelchair wheels must be locked at all times when the 
elevator is moving.

NOTE

WARNING

WARNING

Summary of Contents for Orion MRL

Page 1: ...OWNER S MANUAL To Be Retained by Owner After Installation by Authorized Savaria Dealer Part No 001132 18 m09 2019 Orion MRL Commercial Elevator ...

Page 2: ... more frequently where usage environment or local jurisdiction requires As the Owner you are responsible for ensuring that regular service and inspections occur in a timely manner Refer to this manual for specifications operating instructions and maintenance of the Orion MRL Commercial Elevator Upon completion of installation the dealer must provide you with the following information and ensure it...

Page 3: ...LS 9 5 DOOR OPEN BUTTON 10 6 PHONE MONITORING IF APPLICABLE 11 7 EMERGENCY BATTERY LOWERING 12 8 EMERGENCY LIGHT 12 9 EMERGENCY HANDS FREE TELEPHONE OPTIONAL 12 10 MANUAL LOWERING 13 11 OVERSPEED GOVERNOR RESET 13 12 MAINTENANCE 14 13 MAINTENANCE RECORD 15 This product is designed and manufactured to exact specifications Modifications to this product in any way can be dangerous and will void the w...

Page 4: ... all equipment labels at all times Replace any damaged labels immediately Ensurethat only qualified personnelperform maintenance and service on the unit When replacing parts be sure that only genuine Savaria parts are used This unit is intended for use by a mature person who understands its proper operation as set out in this manual Prior to operation make sure that All doors are locked and secure...

Page 5: ...24 mm 51 wide x 51 deep 1295 mm x 1295 mm Cab panel finish Steel panel cab with optional laminates Maximum travel 25 ft 7 6 m Control system Automatic user interface Programmable Logic Controller PLC Distance between 2 landings 18 457 mm minimum Noise level typical installation 68 2 dBA up direction 65 1 dBA down direction Measured at a height equal to motor distance of 1m in front of motor no hoi...

Page 6: ...ar top prop for maintenance Car top safety rail for maintenance Pit switch emergency stop LED lights in stainless steel Recessed plywood floor Upper and lower terminal limits Overspeed governor Two speedsliding doorsfor drywallor masonryhoistway finish Options Two speed steel doors with infrared closing sensors in black architectural white or stainless steel Steel panels with plastic laminate in a...

Page 7: ...s at a landing Alarm Button Figure 1 C This button can be pressed at any time to sound the alarm in case of an emergency Run Stop Keyswitch Figure 1 D In the STOP position the cab stops and the alarm buzzer is activated This key switch must be in the RUN position for normal operation Phase 2 Fire Service Keyswitch Optional Figure 1 E The keyswitch in the ON position enables cab controls as per Cod...

Page 8: ...l Call Station Controls Figure 2 Hall Call Stations are installed at all landings to move the cab to the landing from which you are calling Press the CALL button to call the cab to your landing The position indicator displays the landing the cab is at An optional keyswitch limits the elevator s use to authorized persons only Landing Door Lock The Landing Door lock prevents movement of the cab unle...

Page 9: ...r the cab The doors will close behind you after a few seconds Once inside the cab lock the wheelchair wheels Wheelchair wheels must be locked at all times when the elevator is moving 4 OPERATING FROM THE COP CONTROLS 1 If sitting in the cab in a wheelchair lock the wheelchair wheels If standing in the cab hold on to the handrail 2 Press the appropriate landing button to send the cab to the desired...

Page 10: ...button is located on the Car Operating Panel COP Whenthe elevatoris at a landing level the doors can be opened by pressing the Door Open button Normally the doors will have opened and already closed automatically The Door Open button allows the door to be reopened Figure 3 Door Open Button ...

Page 11: ... be located at the main landing There is a small red Elevator Communications Failure light and a beeper as shown below If the phone line is not functioning the small red light will flash and the beeper will sound to warn users that the emergency phone in the car is not functioning Contact your Authorized Dealer as soon as possible NOTE There is an alarm silence key provided to turn off the beeper ...

Page 12: ...t the selected landing 2 Upon arrival at the desired floor the landing doors will open automatically and you can exit the cab 8 EMERGENCY LIGHT In the event of a main power failure the emergency cab light will light automatically 9 EMERGENCY HANDS FREE TELEPHONE OPTIONAL 1 If your lift is equipped with an Emergency Hands FreeTelephone press and hold down the button in the telephone box to activate...

Page 13: ... to the OFF position 3 Use the manual lowering device to lower the elevator to the lower landing level 4 Obtain the special door release key and open the lower landing door Assist the passenger s from the cab 5 After the passenger s have exited the cab make sure the hoistway door is closed and lock the door behind you 6 Return the special door release key to its original storage area After use of ...

Page 14: ...horized Savaria Dealer Additional inspections may be required depending on usage 1 Tighten all rail and cab fastening bolts 2 Lubricate the counterweight rails with a light grease such as white lithium 3 Inspect the traveling cable for wear Replace if any cuts or damage to the jacket is evident 4 Inspect the elevator cables for wear or damage and replace if necessary Always replace the safety wash...

Page 15: ...15 Part No 001132 18 m09 2019 Orion MRL Owner s Manual 13 MAINTENANCE RECORD Date Time Reason for Call Comments Dealer ...

Page 16: ...er Drive Brampton Ontario L6T 5E1 Canada www savaria com For service or questions about this product please contact your installing dealer DEALER NAME _________________________________________________ DEALER PHONE _________________________________________________ Authorized Savaria Dealer ...

Reviews: