P3.92
Range 1 of position: Setting 1
Default value
0
P3.93
Range 1 of position: Setting 2
Default value
0
P3.94
Range 2 of position: Setting 1
Default value
0
P3.95
Range 2 of position: Setting 2
Default value
0
Setting range
−2000000000 to 2000000000 [Units]
The current servo motor position is detected.
Assign “Position range1 (83)” function to the EOUTn terminal.
If the setting of range 1 of position - setting 1 (P3.92) is smaller than the setting of range 1 of position - setting
2 (P3.93) and the position specified for range 1 of position - setting 1 (P3.92) passes during forward motion,
the range 1 of position signal undergoes OFF-to-ON transition.
If the position specified for range 1 of position - setting 2 (P3.93) passes, the range 1 of position signal
undergoes ON-to-OFF transition.
Regarding “Position range 2 (84)”, it also can be corresponded to the parameters P3.94 to 95 as last setting.
This function is enabled after homing completion or position pre-set.