161
Data type
Data name
Address
(hex.)
Applicable
FC
Format
(with a sign)
Setting range
(default value)
03h 10h
Positioning
data 15
Positioning M
code
60A8
○
○
Refer to“3.5 address
supplementary
description”(No)
-
Stop timer
60AA
○
○
1h = 0.01 [ms] (
※
)
0.00
~
655.35 (0.00)
Stop position
60AC
○
○
1h = 1 [unit](Yes)
0
~
±2000000000
(0)
Rotation speed
60AE
○
○
1h = 0.01 [r/min](No)
0.01
~
Max. rotation
speed (0.01)
Acceleration time
60B0
○
○
1h = 0.1 [ms](No)
0.0
~
99999.9 (0.0)
Deceleration time
60B2
○
○
Positioning
data
Positioning data 1-15
D000~D01
C
○
○
Refer to ”7.3.5
address
supplementary
description ”
-
(
※
) By setting P1.31 (selection of deviation unit), 0 and 1 are defined as unit and pulse, respectively.
(
※
) Set 0:0.01 [ms]/1:0.001 [ms] according to P2.42 (stop timing decimal point position).
·Coil address
Coil address list
Coil type
Coil name
Address
(hex.)
Applicable FC
01h
05h
0Fh
Communication EI
signal
EI9 Signal
0208
○
○
○
~
~
EI24 Signal
0217
Communication
EOUT signal
EOUT6 Signal
0305
○
×
×
~
~
EOUT21 Signal
0314
Hardware EI
signal
EI1 Signal
0400
○
×
×
~
~
EI8 Signal
0407
Hardware EOUT
signal
EOUT1 Signal
0500
○
×
×
~
~
EOUT5 Signal
0504
7.3.5 Address supplementary description
·
Control mode, Action mode, Alarm at present, Alarm history
Each piece of data in the control mode, action mode, alarm at present, and alarm history is the code data of 1
byte.
DATA
4byte
00h
00h
00h
Code