31
Example: Adopt the internal power and perform the short circuit between the pin 1 and pin 37 of the driving
interface. Do not connect SIGN+ or PULS+; SIGN-/PULS- should be connected to the pin 38 of the
CN3 that is connected to Y0/Y1 and COM of the PLC respectively.
●
High speed pulse (Max.4MHz)
High speed pulse is fixed to differential input , twisted-pair is suitable for wiring.
● Pulse input has three modes as the Motion table below:
2.9.4 Feedback encoder signal outputs by frequency division
Encoder pulse signal can be output to a host controller by line drive output after it was set the required
frequency. It has line drive output and open collector output.
Pulse command form
Symbol
Forward rotating
Reverse
rotating
Set value
Pulse symbol
SIGN
PULS
P1.03= 00/03/10
Command pulse plus symbol
SIGN PLUS pulse
Forward rotating pulse
Reverse rotating pulse
SIGN
PULS
P1.03= 01/04/11
Forward rotating pulse /
Reverse rotating pulse
A phase pulse
B phase pulse
SIGN
PULS
P1.03= 02/05/12
A /B Phase command pulse