73
5.2.6 List of parameter setting(Output terminal function)
Parameter
Name
Default
value
Control mode
Position Speed Torque
*
P3.51
EOUT 1 signal assignment
1
○
○
○
P3.52
EOUT 2 signal assignment
2
P3.53
EOUT 3 signal assignment
76
P3.54
EOUT 4 signal assignment
0
P3.55
EOUT 5 signal assignment
0
P3.56
Communication EOUT 6 signal assignment
0
P3.57
Communication EOUT 7 signal assignment
0
P3.58
Communication EOUT 8 signal assignment
0
P3.59
Communication EOUT 9 signal assignment
0
P3.60
Communication EOUT 10 signal assignment
0
P3.61
Communication EOUT 11 signal assignment
0
P3.62
Communication EOUT12 signal assignment
0
P3.63
Communication EOUT13 signal assignment
0
P3.64
Communication EOUT14 signal assignment
0
P3.65
Communication EOUT15 signal assignment
0
P3.66
Communication EOUT16 signal assignment
0
P3.67
Communication EOUT17 signal assignment
0
P3.68
Communication EOUT18 signal assignment
0
P3.69
Communication EOUT19 signal assignment
0
P3.70
Communication EOUT20 signal assignment
0
P3.71
Communication EOUT21 signal assignment
0
P3.81
Analog output 1 signal assignment
0
○
○
○
P3.82
Analog output 2 signal assignment
0
○
○
○
P3.83
Analog output 1 scale
10.0
○
○
○
P3.84
Analog output 1 offset
0
○
○
○
P3.85
Analog output 2 scale
10.0
○
○
○
P3.86
Analog output 2 offset
0
○
○
○
P3.87
Analog output 1/2 output format
0
○
○
○
P3.88
Command pulse frequency sampling time for analog
output
3
○
-
-
P3.89
Feedback speed sampling time for analog output
1
○
○
○
*
P3.90
Servo motor model setting
00
○
○
○
P3.92
Range 1 of position: Setting 1
0
○
-
-
P3.93
Range 1 of position: Setting 2
0
○
-
-
P3.94
Range 2 of position: Setting 1
0
○
-
-
P3.95
Range 2 of position: Setting 2
0
○
-
-