5HSDLUDQG0DLQWHQDQFH
6DYL5)5HOD\5)5DQG5)5,QVWDOODWLRQ*XLGH
14. From the range of 10 to 250 (the factory setting is CH 100),
determine the channel to use.
The new channel should be at least twenty
channels from the factory setting in order to
prevent interference.
15. Type ATS61=[insert new channel number] and press
Enter to set the new transmit channel.
16. Type ATS62=[insert new channel number] and press
Enter to set the new receive channel.
17. Type AT&V1 and press Enter to display the S Register
settings on the screen.
18. Verify that S Registers 61 and 62 are set to the channel that
you selected in Step 14. If not, repeat Steps 15 through 17.
19. Type AT&W to store the new configuration.
20. Remove the RS-485 adapter cable.
21. Disconnect and reconnect the power to the RFR-100 to return
it to data mode.