Warnings
2
READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
I. SAFETY PRECAUTIONS
To prevent electrocution and/or death make sure power is off at the breaker.
Avoid touching/installing the M4 controller box during electrical storms. Death
or serious injury may result due to lightning surges through the system.
Be sure to check local electrical codes for grounding electrical boxes via
the approved method (internal conduit ground, external box ground wire to
grounding rod, etc.)
Use approved conduit routed by approved methods to conduit fittings on the
box.
For DMX based units, do not install data cables in the same conduit as power
cables to prevent communication problems.
Be sure the mounting surface is able to support the load of the controller. Use
all four mounting holes to secure the controller.
There are no customer serviceable components inside the M4 controller. Only
qualified electricians should open the box for installation of the power and LED
accessories connections. All connections should enter through an approved
conduit method.
LED accessories are low voltage and should never be electrically connected
to any power source other than the appropriate M4 controller connector (J5
to J8). Wires must be connected properly to avoid permanently damaging the
LED accessory.
1.
2.
3.
4.
5.
6.
7.
8.
WARNING