EN
9
9
Fitting the hood body
• Open the doors/the door (See section Open Panels).
• Remove the Metal grease filters using the handles
provided.
• Adjust the two screws
Vr
, in the brackets
11a,
so that
they are at the start of their travel.
• Hook the hood body to the two brackets
11a
.
• From the inside of the hood body, turn screws
Vr
to
level the hood body itself.
• Fasten the safety screw
12a
.
• Close the doors/the door again.
12a
Vr
11a
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to
the chimney using either a rigid pipe ø 160 or 125 mm,
the choice of which is left to the installer.
• To install a ø 125 mm air exhaust connection, insert
the reducer flange
9
on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps
(not supplied).
• Remove possible charcoal filters.
ø 160
9
ø 125