EN
1
11
Installing of the chimney and fixing of the hood
When the hood is installed in recycling version the chimney
has to be positioned with the slots upwards. When the hood is
installed in ducting version it has to be positioned in the
opposite way.
• Place the chimney on the frame and fix it to the upper part of
it with the earlier removed screws. When installing the hood
in recycling version make sure that the slots correspond to
the air outlet of the recycling air outlet piece
15
.
• Open the lighting unit by slightly pulling the notch. Remove
the unit from the hood by sliding the fixing pivot.
• Remove the filter pushing it towards the back side of the
hood unit and simultaneously pulling downwards.
• Remove possible charcoal filters.
• In order to fix the hood body to the frame insert the 4 screws
12f
in their seats. It is necessary to leave at least 4-5 mm gap
between the screw heads and the frame plate.
• Hook the hood canopy to the frame and turn it to the left
until it reaches the stop, then lock the screws immediately to
prevent the hood canopy from falling out accidentally.
2
1
ELECTRICAL CONNECTION
• Connect the Hood to the mains power supply, inserting a
two-pole cut-out switch with contact aperture of at least 3
mm along the line.
• Ensure that the supply cable connector is properly inserted
into the Suction device socket.
• Remember to connect the two cables inside the hood. One
of the cables must be connected to the command and the
other to the lights.
• Hook up the Commands connector
Cmd
. Please do not pull
the cable in order to avoid the cable from detaching.
• Hook up the Spotlights connector
Lux
to the socket provided
behind the lighting unit cover.
• For the Recirculation Version, fit the Activated Charcoal
Odour Filter.
• Replace the filters and the lighting unit.
Cmd
Lux