background image

2

3. SAFETY RULES

1.  To reduce the risk of electric shock, insure 

electricity has been turned off at the circuit 
breaker or fuse box before beginning.

2.  All wiring must be in accordance with the 

National Electrical Code and local electrical 
codes. Electrical installation should be 
performed by a qualified licensed 
electrician.

3. 

WARNING:

 To reduce the risk of electrical 

shock and fire, do not use this fan with any 
solid-state fan speed control device.

4. 

WARNING:

 To reduce the risk of personal 

injury, use only the two steel screws (and 
lock washers) provided with the outlet box 
for mounting to the outlet box. Most outlet 
boxes commonly used for the support of 
lighting fixtures are not acceptable for fan 
support and may need to be replaced, 
consult a qualified electrician if in doubt.

5.  The outlet box and support structure must 

be securely mounted and capable of 
reliably supporting a minimum of 50 
pounds. Use only CUL Listed outlet boxes 
marked 

"FOR FAN SUPPORT"

.

6. The fan must be mounted with a minimum 

of 7 feet clearance from the trailing edge of 
the blades to the floor.

7.  Do not operate reversing switch while fan 

blades are in motion. Fan must be turned 
off and blades stopped before reversing 
blade  direction.

8. Avoid placing objects in the path of the 

blades.

9.    To avoid personal injury or damage to the 

fan and other items, be cautious when 
working around or cleaning the fan.

10. Do not use water or detergents when 

cleaning the fan or fan blades. A dry dust 
cloth or lightly dampened cloth will be 
suitable for most cleaning.

11.  After marking electrical connections, spliced 

conductors should be turned upward and 
pushed carefully up into outlet box. The 
wires should be spread apart with the 
grounded conductor and the equipment- 
grounding conductor on one side of the 
outlet box.

12.  Electrical diagrams are reference only. Light 

kit that are not packed with the fan must be 
CUL Listed and marked suitable for use with 
the model fan you are installing. Switches 
must be CUL General Use Switches. Refer to 
the Instructions packaged with the light kits 
and switches for proper assembly.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC 

SHOCK OR PERSONAL INJURY, MOUNT FAN 

TO OUTLET BOX MARKED 

"ACCEPTABLE 

FOR FAN SUPPORT".

WARNING

TO REDUCE THE RISK OF PERSONAL INJURY, 

DO NOT BEND THE BLADE BRACKETS (ALSO 

REFERRED TO AS FLANGES) DURING 

ASSEMBLY OR AFTER INSTALLATION. DO NOT 

INSERT OBJECTS IN THE PATH OF THE BLADES.

ATTENTION

 

Under the Energy Policy Act of 2005, 

federal regulations require all ceiling fans 

with light kits manufactured or imported 

after January 1, 2009, to limit the total 

wattage consumed by the light kit to 190 

watts. Therefore, this product is equipped 

with a 190W limiting device. If lamping 

exceeds 190 watts, the light kit will shut 

off automatically until the proper wattage 

of bulbs are installed. Reset the light kit by 

turning it off, replacing the bulbs with the 

correct wattage, and then turning the 

light kit back on.

Summary of Contents for 52-831-5RV

Page 1: ...READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V 60Hz CUL LISTED MODEL AC 552A MODEL 52 831 5RV CEILING FAN OWNER S MANUAL ...

Page 2: ...3 l Pull chains and fobs 2 m Package hardware 1 Mounting hardware screws 2 lock washers 2 star washers 2 wire nuts 3 wood screws 2 washers 2 2 Blade attachment hardware screws 16 fiber washers 16 3 Blade arm hardware screws with lock washers 11 4 Safety cable hardware wood screw lock washer metal washer 5 Extra plastic plug 6 Balance Kit Philips screw driver Blade screw driver 11 mm wrench Step la...

Page 3: ...cleaning the fan 10 Do not use water or detergents when cleaning the fan or fan blades A dry dust cloth or lightly dampened cloth will be suitable for most cleaning 11 After marking electrical connections spliced conductors should be turned upward and pushed carefully up into outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side o...

Page 4: ...eight of the fan at least 50 lbs Do not use plastic outlet boxes Figures 1 2 and 3 are examples of different ways to mount the outlet box Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling Fig 3 To hang your fan where there is an existing fixture but no ceiling joist you may need an installation hanger bar as shown in Figure 4 Outlet box...

Page 5: ...hanger bracket as shown in Fig 5 Step 2 Secure the hanger bracket to the ceiling outlet box with the screws and washers provided with your outlet box Step 3 Remove the canopy ring from the canopy Fig 6 Step 4 Remove the hitch pin lock pin and set screws from the top of the motor assembly Step 5 Route wires exiting from the top of the fan motor through the coupling cover and canopy and then through...

Page 6: ...outlet box securely 5 Remove three of the six screws and lock washers every other one from the collar of top motor Fig 9 6 Place the ceiling canopy over the collar at the top of the motor Align the mounting holes with the holes in the motor and fasten using the screws and lock washers provided Fig 9 7 Tighten the mounting screws securely Fig 9 WARNING Failure to completely tighten the three screws...

Page 7: ...te neutral household wire Step 3 Connect the fan ground wire green to the household ground wire Step 4 After connecting the wires spread them apart so that the green and white wires are on one side of the outlet box and the black and the blue wires are on the other side Step 5 Turn the connecting nuts upward and push the wiring into the outlet box Figures 13 and 14 illustrate the wiring connection...

Page 8: ...UND WIRING BOX BLK WH BLUE BLK WH FAN LIGHT WH WH BLUE BLK LIGHT FAN 8 FINISHING THE INSTALLATION STANDARD CEILING INSTALLATION Slide canopy up to the ceiling as shown in Figure 15 Make sure you place the wires safely into the outlet box Secure the canopy to the hanger bracket with the four screws with your fan CLOSE TO CEILING INSTALLATION Remove the fan from the hook on the hanger bracket Secure...

Page 9: ...motor using the screws supplied Fig 17 Figure 17 Figure 18 10 INSTALLATING THE MOUNTING PLATE 1 Remove the 1 of 3 screws from the mounting ring and loosen the other 2 screws Do not remove 2 Place the key holes on the mounting plate over the 2 screws previously loosened from the mounting ring turn mounting plate until it locks in place at the narrow section of the key holes Secure by tightening the...

Page 10: ...ig 20 4 Restore power and your light kit is ready for operation 9 Figure 19 Figure 20 11 INSTALLING THE LIGHT KIT NOTE Before starting installation disconnect the power by turning off the circuit breaker or removing the fuse at fuse box Step 1 Remove the 3 screws from the mounting plate Step 2 While holding the light kit under your fan snap together the wire connection plug Fig 19 Step 3 Install t...

Page 11: ...downward airflow creates a cooling effect as shown in Fig 22 This allows you to set your air conditioner on a warmer setting without affecting your comfort Cool weather Reverse An upward airflow moves warm air off the ceiling area as shown in Fig 23 on a cooler setting without affecting your comfort 13 FAN WITHOUT LIGHT KIT OPTIONAL 1 Disassemble the switch housing from the light kit by removing n...

Page 12: ...t fan wobbling problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance Rotate the fan until the next blade is positioned for measurement Repeat for each blade The distance deviation should be equal within 1 8 3 Use the enclosed Blade Balancing Kit if the blade wobble is still noticeable 4 If the...