3. SAFETY RULES

1.  To reduce the risk of electric shock, ensure 

electricity has been turned off at the circuit 
breaker or fuse box before beginning.

2.   All wiring must be in accordance with the 

National Electrical Code and local electrical 
codes. Electrical installation should be 
p e r f o r m e d  b y  a  q u a l i f i e d  l i c e n s e d 
electrician.

3. 

WARNING:

 To reduce the risk of electrical 

shock and fire, do not use this fan with any 
solid-state fan speed control device.

4. 

WARNING:

 To reduce the risk of fire, electric 

shock, or personal injury, mount to outlet 
box marked "acceptable for fan support of 
15.8 kg (35 lbs.) or less" and use mounting 
screws provided with the outlet box. Most 
outlet boxes commonly used for the 
support of light fixtures are not acceptable 
for fan support and may need to be 
replaced. Due to the complexity of the 
installation of this fan, a qualified licensed 
electrician is strongly recommended.

5.  The outlet box and support structure must 

be securely mounted and capable of 
reliably supporting a minimum of 50 
pounds. Use only cUL Listed outlet boxes 
marked

 "FOR FAN SUPPORT".

6. The fan must be mounted with a minimum 

of 7 feet clearance from the trailing edge 
of the blades to the floor.

7.  Do not operate reversing switch while fan 

blades are in motion. Fan must be turned 
off and blades stopped before reversing 
blade  direction.

8.  Avoid placing objects in the path of the 

blades.

9. 

To avoid personal injury or damage to the 

fan and other items, be cautious when 
working around or cleaning the fan.

10. Do not use water or detergents when 

cleaning the fan or fan blades.  A dry dust 
cloth or lightly dampened cloth will be 
suitable for most cleaning.

11. After marking electrical connections, 

spliced conductors should be turned 
upward and pushed carefully up into 
outlet box. The wires should be spread 
apart with the grounded conductor and 
the equipment-grounding conductor on 
one side of the outlet box.

12.  Electrical diagrams are only for reference. 

Light kit that are not packed with the fan 
must be cUL Listed and marked suitable 
for use with the model fan you are 
installing. Switches must be cUL General 
Use Switches. Refer to the instructions 
packaged with the light kits and switches 
for proper assembly.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC 

SHOCK OR PERSONAL INJURY, MOUNT FAN 

TO OUTLET BOX MARKED 

"ACCEPTABLE 

FOR FAN SUPPORT".

WARNING

TO REDUCE THE RISK OF PERSONAL INJURY, 

DO NOT BEND THE BLADE BRACKETS (ALSO 

REFERRED TO AS FLANGES) DURING 

ASSEMBLY OR AFTER INSTALLATION. DO NOT 

INSERT OBJECTS IN THE PATH OF THE BLADES.

Summary of Contents for 52-840-5CN-196

Page 1: ...READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V 60Hz CUL LISTED MODEL AC 552DL MODEL 52 840 5CN 196 CEILING FAN OWNER S MANUAL ...

Page 2: ...bs 3 j Receiver 6 wire nuts k Transmitter holder 2 mounting screws 23A 12V battery l Package hardware 1 Mounting hardware screws 2 lock washers 2 star washers 2 wire nuts 3 wood screws 2 2 Blade attachment hardware screws with lock washers 16 3 Safety cable hardware wood screws 2 lock washers 2 metal washers 2 4 Balance Kit Philips screw driver Blade screw driver 11 mm wrench Step ladder Wire cutt...

Page 3: ...of the blades to the floor 7 Do not operate reversing switch while fan blades are in motion Fan must be turned off and blades stopped before reversing blade direction 8 Avoid placing objects in the path of the blades 9 To avoid personal injury or damage to the fan and other items be cautious when working around or cleaning the fan 10 Do not use water or detergents when cleaning the fan or fan blad...

Page 4: ...eight of the fan at least 50 lbs Do not use plastic outlet boxes Figures 1 2 and 3 are examples of different ways to mount the outlet box Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling Fig 3 To hang your fan where there is an existing fixture but no ceiling joist you may need an installation hanger bar as shown in Figure 4 Outlet box...

Page 5: ...y cable and wires exiting from the top of the fan motor through the collar cover canopy cover canopy and then through the ball downrod Fig 7 Step 7 Align the holes at the bottom of the downrod with the holes in the collar on top of the motor housing Fig 7 Carefully insert the hanger pin through the holes in the collar and downrod Be careful not to jam the pin against the wiring inside the downrod ...

Page 6: ...eck to make sure the switches on transmitter and receiver are set to the same position any combination of settings will operate the fan as long as the transmitter and receiver are set to the same position Figure 10 Step 1 Figure 11 Insert the receiver into the mounting bracket with the flat side of the receiver facing the ceiling Step 2 Figure 12 Motor to Receiver Electrical Connections Connect th...

Page 7: ...tween the transmitting unit and the fan s receiving unit 8 FINISHING THE INSTALLATION Step 1 Tuck connections neatly into ceiling outlet box Step 2 Slide the canopy up to hanger bracket and place the key hole on the canopy over the screw on the hanger bracket turn canopy until it locks in place at the narrow section of the key holes Step 3 Align the circular hole on canopy with the remaining hole ...

Page 8: ...ectors Fig 15 Step 3 Tuck connections neatly into mounting ring Place the light plate key holes over the 2 screws previously loosened from the mounting ring turn light kit until it locks in place at the narrow section of the key holes Secure by tightening the 2 screws previously loosened and the one previously removed Fig 16 9 ATTACHING THE FAN BLADES Caution Remove 5 rubber packing mounts and dis...

Page 9: ...ng the fuse at fuse box Turning power off using the fan switch is not sufficient to prevent electric shock Step 1 Install 3 x 4W LED bulbs included Step 2 Raise the glass shade frame assembly up to the light kit and secure with the 3 screws provided Fig 16 Step 3 Restore power and your light kit is ready for operation Glass shade frame assembly Bulbs Light kit Screws ...

Page 10: ...rd or reverse This button are NO function on this fan please use reverse switch to reverse fan D button This button controls the light Press and release the button to turn the light ON or OFF Press and hold the button to set the desired brightnes s The light key has an auto resume it will stay at the same brightness as the last time it was turned off 12 INSTALLING THE BATTERY Insert the 23A 12V ba...

Page 11: ...olish 4 There is no need to oil your fan The motor has permanently lubricated bearings 14 CARE OF YOUR FAN IMPORTANT MAKE SURE THE POWER IS OFF AT THE ELECTRICAL PANEL BOX BEFORE YOU ATTEMPT ANY REPAIRS REFER TO THE SECTION MAKING ELECTRICAL CONNECTIONS Figure 19 Figure 20 The Reverse switch is located on the motor housing Slide the switch to the Left for warm weather operation Slide the switch to...

Page 12: ...6 Do not connect the fan with wall mounted variable speed control s 7 Make sure the upper canopy is a short distance from the ceiling It should not touch the ceiling 1 Do not connect the fan with wall mounted variable speed control s 2 Make sure the dip switches are set correctly 1 Check that all blade and blade arm screws are secure 2 Most fan wobbling problems are caused when blade levels are un...

Reviews: