background image

7

Figure 13

Figure 14

Mounting ring

Mounting 

plate

Screws

11. INSTALLING THE 

LIGHT KIT 

NOTE: 

Before 

starting 

installation, 

disconnect  the  power  by  turning  off  the 
circuit  breaker  or  removing  the  fuse  at 
fuse box. Turning power off using the fan 
switch  is  not  sufficient  to  prevent  electric 
shock.

1. Remove the screws from the mounting 
plate under the fan motor.

2.    While  holding  the  switch  housing 
under  your  fan,  snap  together  the  wire 
connection plug. (Fig. 14)

3. Raise the light kit to the mounting plate 
until  the  holes  in  light  kit  and  mounting 
plate  line  up.  Reinsert  screws  to  secure  in 
place. (Fig. 14)

Mounting 

plate

Connection plugs

Light kit

Screws

10. INSTALLATING THE 

MOUNTING PLATE

1.  Remove  the  1  of  3  screws  from  the 

mounting  ring  and  loosen  the  other  2 
screws. (Do not remove)

2.  Place  the  key  holes  on  the  mounting 

plate  over  the  2  screws  previously 
loosened  from  the  mounting  ring,  turn 
mounting plate until it locks in place at 
the  narrow  section  of  the  key  holes. 
Secure  by  tightening  the  2  screws 
previously  loosened  and  the  one 
previously removed. (Fig. 13)

Summary of Contents for 52P-646-5RV-187

Page 1: ...READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V 60Hz CUL LISTED MODEL AC 552A MODEL 52P 646 5RV 187 52P 646 5RV 323 CEILING FAN OWNER S MANUAL ...

Page 2: ... Fan motor assembly f Set of blades bracket 5 g Mounting plate h Light kit i Glass shade j 3 x40W candelabra bulbs k Pull chain and fob 2 l Package hardware 1 Mounting hardware screws 2 lock washers 2 star washers 2 wire nuts 3 wood screws 2 washers 2 2 Blade attachment hardware screws 16 fiber washers 16 3 Blade arm hardware screws with lock washers 11 4 Safety cable hardware wood screw lock wash...

Page 3: ...cleaning the fan 10 Do not use water or detergents when cleaning the fan or fan blades A dry dust cloth or lightly dampened cloth will be suitable for most cleaning 11 After marking electrical connections spliced conductors should be turned upward and pushed carefully up into outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side o...

Page 4: ...eight of the fan at least 50 lbs Do not use plastic outlet boxes Figures 1 2 and 3 are examples of different ways to mount the outlet box Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling Fig 3 To hang your fan where there is an existing fixture but no ceiling joist you may need an installation hanger bar as shown in Figure 4 Outlet box...

Page 5: ... 5 Step 3 Pass the 120 volt supply wires through the center hole in the ceiling hanger bracket as shown in Fig 6 Step 4 Secure the hanger bracket to the ceiling outlet box with the screws and washers provided with your outlet box Step 5 Remove the hanger pin lock pin and set screws from the top of the motor assembly Step 6 Route wires exiting from the top of the fan motor through the canopy cover ...

Page 6: ...nnect the fan supply black wire and light supply blue wire to the black household supply wire as shown in Fig 10 Step 2 Connect the neutral fan white wire to the white neutral household wire Step 3 Connect the two green fan ground wires located on the mounting plate and motor to the household ground wire Step 4 After connecting the wires spread them apart so that the green and white wires are on o...

Page 7: ...hers 8 FINISHING THE INSTALLATION Step 1 Tuck connections neatly into ceiling outlet box Step 2 Slide the canopy up to hanger bracket and place the key hole on the canopy over the screw on the hanger bracket turn canopy until it locks in place at the narrow section of the key holes Step 3 Align the circular hole on canopy with the remaining hole on the hanger bracket secure by tightening the two s...

Page 8: ...ire connection plug Fig 14 3 Raise the light kit to the mounting plate until the holes in light kit and mounting plate line up Reinsert screws to secure in place Fig 14 Mounting plate Connection plugs Light kit Screws 10 INSTALLATING THE MOUNTING PLATE 1 Remove the 1 of 3 screws from the mounting ring and loosen the other 2 screws Do not remove 2 Place the key holes on the mounting plate over the ...

Page 9: ...ews 12 INSTALLING THE LIGHT BULBS GLASS SHADE NOTE Before starting installation discon nect the power by turning off the circuit breaker or removing the fuse at fuse box Turning power off using the fan switch is not sufficient to prevent electric shock 1 Install 3 x 40W candelabra bulbs included 2 Insert the fan pull chain through the eyelet in the shade and cap Also insert the light kit pull chai...

Page 10: ... warm or cool weather depend on factors such as the room size ceiling height number of fans and so on The slide switch controls directions forward switch left or reverse switch right Warm weather Forward A downward airflow creates a cooling effect as shown in Fig 17 This allows you to set your air conditioner on a warmer setting without affecting your comfort Cool weather Reverse An upward airflow...

Page 11: ...iod Most noise associated with a new fan disappear during this time 5 If using an optional light kit make sure the screws securing the glassware are tight Check that light bulb is also secure 6 Some fan motors are sensitive to signals from solid state variable speed controls If you have installed this type of control choose and install another type of control 7 Make sure the upper canopy is a shor...

Reviews: