6. INSTALLATION OF 

SAFETY SUPPORT

An additional safety support is provided to 
prevent the fan from falling. Secure the 
safety cable to the ceiling joist with screw 
and washer, as illustrated in Figure 11. 

7. MAKE THE ELECTRIC 

CONNECTIONS

WARNING:

 To avoid possible electrical 

shock, be sure electricity is turned off at 
the main fuse box before wiring.

NOTE:

 This remote control unit is 

equipped with 16 code combinations to 
prevent possible interference from or to 
other remote units. The frequency 
switches on your receiver and transmitter 
have been preset at the factory. Please 
recheck to make sure the switches on 
transmitter and receiver are set to the 
same position, any combination of 
settings will operate the fan as long as the 
transmitter and receiver are set to the 
same position. (Figure 12)

Step 1.

 (Figure 13) Insert the receiver into 

the mounting bracket with the flat side of  
the receiver facing the ceiling. 

Step 2.

 (Figure 14) Motor to Receiver 

Electrical Connections: Connect the black  
wire from the fan to black wire marked 
"TO MOTOR L". Connect the white wire  
from the fan to the white wire marked "TO 
MOTOR N" from the receiver. Connect the 
blue wire from the fan to the blue wire 
marked "For Light" from the receiver. 
Secure the wire connections with the 
plastic wire nuts provided.

 

Hanger bracket

Safety cable

Figure 11

Figure 12

Figure 13

Receiver

Hanger
bracket

 

Code switch

ON 

ON 

Summary of Contents for 60-820-613-13

Page 1: ...READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V 60Hz CUL LISTED MODEL AC 568F760 MODEL 60 820 613 13 60 820 6SV SN CEILING FAN OWNER S MANUAL ...

Page 2: ...6 wire nuts l Transmitter holder 2 mounting screws 23A 12V battery m E27 9W LED bulbs 2 n Package hardware 1 Mounting hardware screws 2 lock washers 2 star washers 2 wire nuts 3 wood screws 2 washers 2 2 Blade attachment hardware screws with washers 19 3 Safety cable hardware wood screw 1 lock washer 1 metal washer 1 4 Balance Kit 1 Philips screw driver Blade screw driver 11 mm wrench Step ladder ...

Page 3: ... when cleaning the fan or fan blades A dry dust cloth or lightly dampened cloth will be suitable for most cleaning 11 After marking electrical connections spliced conductors should be turned upward and pushed carefully up into outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box 12 Electrical diagrams are only f...

Page 4: ... weight of the fan at least 50 lbs Do not use plastic outlet boxes Figures 1 2 and 3 are examples of different ways to mount the outlet box Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling Fig 3 To hang your fan where there is an existing fixture but no ceiling joist you may need an installation hanger bar as shown in Figure 4 Outlet b...

Page 5: ...th your outlet box Step 3 Remove the hitch pin lock pin and set screws from the top of the motor assembly Step 4 Route wires exiting from the top of the fan motor through the coupling cover canopy and then through the ball downrod Fig 6 Step 5 Align the holes at the bottom of the downrod with the holes in the collar on top of the motor housing Fig 6 Carefully insert the hitch pin through the holes...

Page 6: ...the ceiling canopy over the collar at the top of the motor Align the mounting holes with the holes in the motor and fasten using the screws and lock washers provided Fig 9 6 Tighten the mounting screws securely WARNING Failure to completely tighten the three screws in step 5 could result in fan loosening and possibly falling 7 Hang the fan on the hook of the hanger bracket Be certain that the cano...

Page 7: ...eck to make sure the switches on transmitter and receiver are set to the same position any combination of settings will operate the fan as long as the transmitter and receiver are set to the same position Figure 12 Step 1 Figure 13 Insert the receiver into the mounting bracket with the flat side of the receiver facing the ceiling Step 2 Figure 14 Motor to Receiver Electrical Connections Connect th...

Page 8: ...box has a ground wire green or bare copper connect it to the fan ground wires otherwise connect the hanging bracket ground wire to the mounting bracket Secure the wire connection with a plastic nut provided After connecting the wires spread them apart so that the green and white wires are on one side of the outlet box and black and blue wires are on the other side Carefully tuck the wire connectio...

Page 9: ... screws previously loosened and the one previously removed Fig 18 Mounting ring Mounting plate Screws Blade Screws with washers Slot Figure 16 Outlet box Hanger bracket Ceiling canopy Screws 9 ATTACHING THE FAN BLADES Insert the blades through the blade slot in the decorative housing Align the holes in blade and blade bracket secure with the screws and washers provided Fig 17 CLOSE TO CEILING INST...

Page 10: ...lace the light plate key holes over the 2 screws previously loosened from the mounting ring turn light kit until it locks in place at the narrow section of the key holes secure by tightening the 2 screws previously loosened and the one previously removed Fig 19 12 INSTALLING THE LIGHT BULB GLASS SHADE 1 Install 2 x E27 9W LED bulb included 2 Raise glass shade up against the mounting plate and secu...

Page 11: ...on controls the light Press and release the button to turn the light ON or OFF Press and hold the button to set the desired brightness The light key has an auto resume it will stay at the same brightness as the last time it was turned off Speed settings for warm or cool weather depend on factors such as the room size Ceiling height number of fans and so on 13 INSTALLING THE BATTERY Insert the 23A ...

Page 12: ...olish 4 There is no need to oil your fan The motor has permanently lubricated bearings 15 CARE OF YOUR FAN IMPORTANT MAKE SURE THE POWER IS OFF AT THE ELECTRICAL PANEL BOX BEFORE YOU ATTEMPT ANY REPAIRS REFER TO THE SECTION MAKING ELECTRICAL CONNECTIONS Figure 23 Figure 24 The Reverse switch is located on the motor housing Slide the switch to the Left for warm weather operation Slide the switch to...

Page 13: ...6 Do not connect the fan with wall mounted variable speed control s 7 Make sure the upper canopy is a short distance from the ceiling It should not touch the ceiling 1 Do not connect the fan with wall mounted variable speed control s 2 Make sure the dip switches are set correctly 1 Check that all blade and blade arm screws are secure 2 Most fan wobbling problems are caused when blade levels are un...