5
6. MAKE THE ELECTRIC
CONNECTIONS
WARNING:
To avoid possible electrical shock,
be sure electricity is turned off at the main
fuse box before wiring.
NOTE:
This remote control unit is equipped
with 16 code combinations to prevent possible
interference from or to other remote units.
The frequency switches on your receiver and
transmitter have been preset at the factory.
Please recheck to make sure the switches on
transmitter and receiver are set to the same
position, any combination of settings will operate
the fan as long as the transmitter and receiver
are set to the same position. (Figure 9)
Step 1.
(Figure 10) Insert the receiver into the
mounting bracket with the flat side of the receiver
facing the ceiling.
Step 2.
(Figure 11) Motor to Receiver Electrical
Connections: Connect the black wire from the
fan to black wire marked "TO MOTOR L". Connect
the white wire from the fan to the white wire
marked "TO MOTOR N" from the receiver.
Connect the blue wire from the fan to the blue
wire marked "For Light" from the receiver. Secure
the wire connections with the plastic wire nuts
provided.
Step 3.
(Figure 11) Receiver to House Supply
Wires Electrical Connections: Connect the black
(hot) wire from the ceiling to the black wire
marked "AC in L" from the receiver. Connect the
white (neutral) wire from the ceiling to the
white wire marked "AC in N" from the Receiver.
Secure the wire connections with the plastic
wire nuts provided.
Step 4.
(Figure 11) If your outlet box has a
ground wire (green or bare copper) connect it to
the fan ground wires; otherwise connect the
hanging bracket ground wire to the mounting
bracket. Secure the wire connection with a
plastic nut provided. After connecting the wires,
spread them apart so that the green and white
wires are on one side of the outlet box and black
and blue wires are on the other side. Carefully
tuck the wire connections up into the outlet box.
NOTE:
Fan must be installed at a maximum
distance of 30 feet from the transmitting unit
for proper signal transmission between the
transmitting unit and the fan's receiving unit.
Figure 9
Figure 10
Receiver
Hanger
bracket
Code switch
ON
ON
ON
ECE
1234
Figure 11
White (neutral)
White (neutral)
Green or bare
copper (ground)
White ("AC IN N")
White ("to motor N")
Ground
(green)
(Connect to
ground wire on
hanger bracket
if no house
ground wire
exists.)
Outlet box
Black (hot)
Black ("AC IN L")
Black ("to motor L")
Receiver
Blue (for light)
Blue (for light)
Black (motor)