background image

5

6. INSTALLATION OF 

SAFETY SUPPORT

An additional safety support is provided to 
prevent the fan from falling.  Secure the 
safety cable to the ceiling joist with screw 
and washer, as illustrated in Figure 9. 

7. MAKE THE ELECTRIC 

CONNECTIONS

WARNING:

 To avoid possible electrical 

shock, be sure electricity is turned off at 
the main fuse box before wiring.

NOTE:

 This remote control unit is 

equipped with 16 code combinations to 
prevent possible interference from or to 
other remote units. The frequency 
switches on your receiver and transmitter 
have been preset at the factory.  Please 
recheck to make sure the switches on 
transmitter and receiver  are set  to  the 
same position, any combination of settings 
will operate the fan as long as the 
transmitter and receiver are set to the 
same position.(Figure 10)

Step 1.

 (Figure 11)  Insert  the  receiver  

into the mounting bracket  with  the  flat 
side  of  the receiver facing the ceiling. 

Step 2.

 (Figure 12) Motor to Receiver 

Electrical Connections:  Connect  the  black  
wire  from the fan to black wire marked 
"TO MOTOR L". Connect  the  white  wire  
from  the  fan to the white wire marked 
"TO MOTOR N" from the receiver.  Connect  
the blue wire from the fan to the blue wire 
marked "For Light" from the receiver. 
Secure the wire connections with the 
plastic wire nuts provided.

 

Hanger bracket

Safety cable

Figure 9

Figure 10

Figure 11

Code switch

ON 

ON 

Receiver

Hanger
bracket

Summary of Contents for ACROPOLIS

Page 1: ...READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V 60Hz CUL LISTED MODEL AC 552OD MODEL ACROPOLIS CEILING FAN OWNER S MANUAL ...

Page 2: ...ire nuts n Transmitter holder 2 mounting screws o 9 volt battery p Package hardware 1 Mounting hardware screws 2 lock washers 2 star washers 2 wire nuts 3 wood screws 2 2 Blade attachment hardware screws 20 rubber washers 20 3 Blade arm hardware screws with lock washers 11 4 Safety cable hardware wood screws 2 lock washers 2 metal washers 2 5 Balance Kit Philips screw driver Blade screw driver 11 ...

Page 3: ...cleaning the fan 10 Do not use water or detergents when cleaning the fan or fan blades A dry dust cloth or lightly dampened cloth will be suitable for most cleaning 11 After marking electrical connections spliced conductors should be turned upward and pushed carefully up into outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side o...

Page 4: ...materials The outlet box and its support must be able to fully support the moving weight of the fan at least 50 lbs Do not use plastic outlet boxes Figures 1 2 and 3 are examples of different ways to mount the outlet box Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling Fig 3 Outlet box Provide strong support Recessed outlet box Ceiling...

Page 5: ...Step 6 Route wires exiting from the top of the fan motor through the collar cover canopy cover canopy and then through the ball downrod Fig 7 Step 7 Align the holes at the bottom of the downrod with the holes in the collar on top of the motor housing Fig 7 Carefully insert the hanger pin through the holes in the collar and downrod Be careful not to jam the pin against the wiring inside the downrod...

Page 6: ...e sure the switches on transmitter and receiver are set to the same position any combination of settings will operate the fan as long as the transmitter and receiver are set to the same position Figure 10 Step 1 Figure 11 Insert the receiver into the mounting bracket with the flat side of the receiver facing the ceiling Step 2 Figure 12 Motor to Receiver Electrical Connections Connect the black wi...

Page 7: ...mission between the transmitting unit and the fan s receiving unit 8 FINISHING THE INSTALLATION Step 1 Tuck connections neatly into ceiling outlet box Step 2 Slide the canopy up to hanger bracket and place the key hole on the canopy over the screw on the hanger bracket turn canopy until it locks in place at the narrow section of the key holes Step 3 Align the circular hole on canopy with the remai...

Page 8: ...motor using the screws supplied Fig 14 Figure 14 Figure 15 10 INSTALLATING THE MOUNTING PLATE 1 Remove the 1 of 3 screws from the mounting ring and loosen the other 2 screws Do not remove 2 Place the key holes on the mounting plate over the 2 screws previously loosened from the mounting ring turn mounting plate until it locks in place at the narrow section of the key holes Secure by tightening the...

Page 9: ...ame procedure with the black wire connectors Fig 16 Step 3 Tuck connections neatly into mounting plate Place the light plate key holes over the 2 screws previously loosened from the mounting ring turn light kit until it locks in place at the narrow section of the key holes secure by tightening the 2 screws previously l o o s e n e d a n d t h e o n e p r e v i o u s l y removed Fig 16 12 INSTALLIN...

Page 10: ...ff The Reverse switch is located on thetopof themotorhousing Slide the switch to the Left for warmweather operation Slide the switch to the Right for cool weather operation Speed settings for warm or cool weather depend on factors such as the room size Ceiling height number of fans and so on NOTE Wait for fan to stop before changing the setting of the slide switch Warm weather Forward A downward a...

Page 11: ... nut connections are not rubbing against each other or the interior wall of the switch housing CAUTION Make sure main power is off 4 Allow a 24 hour breaking in period Most noise associated with a new fan disappear during this time 5 If using an optional light kit make sure the screws securing the glassware are tight Check that light bulb is also secure 6 Do not connect the fan with wall mounted v...