BATTERY P ROTECTION
T his fridge is equipped with a battery monitor cutting the
compressor in or out in order to protect the battery. When the
"MODE" button is pressed twice, the LED display will be blinking
the current battery monitor state "OFF" or "LO" or "HI" (default
OFF).
T he "SELECT " button during this mode will display the
OFF---+LO---+HI change.
After pre-setting the battery monitor, the LED display will stop
blinking (after a few second), indicating the temperature has been
set (locked). The value by each setting is shown on the below
table. The battery monitor is not a necessary feature for the fridge
to operate. It may be left in the off position at all time.
Battery monitor setting
OFF
LO
HI
Cut out Voltage
1 2V
-
1 0.5V
1 1 .5V
Cut in Voltage
1 2V
-
1 1 .5V
1 2.5V
Cut out Voltage
24V
-
21 .0V
23. 1 V
Cut in Voltage
24V
-
23.1 V
25.0V
- 1 4 -