- 16 -
8. Tilt protection
※
Tilt protection still works when tilted in all directions.Operating angle changes
depending on the tilt speed.
9. Trouble shooting
Fault
Possible cause
Action
Interior
not
cold
Compressor
not
working
No power supplied.
Battery in poor condition.
Check if power is supplied to
electronic unit.
Faulty electronic unit.
Check fuse.
Defrost evaporator.
(see 7.2 Defrosting)
Electronic unit failure.
Check polarity of connectors
and cables.
Tilt protection.
Check refrigerator is horizontal.
Ambient temperature too high.
Insufficient ventilation.
Keep refrigerator sufficiently
ventilated.
Frost on evaporator
Condenser clogged
Clean condenser.
If the problem still persists after going through the chart above, consult an ENGEL
service agent near you. Never disassemble the refrigerator by yourself. Inadequate
repairs can lead to considerable hazards.
Stop
Start
Tilt for 10 seconds
above about
45
〜
65 degrees.
Tilt for 1 second
below about
20
〜
30 degrees.
This refrigerator senses the tilt and stops.