The heater can be placed wherever in the sauna, but for safety and
convenience, follow the minimum safety distances as provided in Fig. 2. Follow
the cubic volumes given in the Technical Data (page 20.). Do not install the
heater to the floor or wall niche. Do not install more than one heater in a
sauna room unless you follow the special instructions for twin-heater
installations. In most countries, there is a law that requires heaters to be
screwed to the floor as provided in Fig. 1a. Install bracket support for safety
purposes Fig. 1b.
The heater gets very hot. To avoid the risk of accidental contact with the
heater, it is recommended that a heater guard be provided.
The cable used for sauna wiring must be HO7RN-F type or its equivalent. A
certified electrician must do the installation of the heater to ensure safety and
reliability. Improper electrical connection can cause electric shock or fire.
(Refer to the electrical diagram in page 13-15).
Heater Installation
9
ENGLISH
A
A
B
100
20 max. 500
HUOM:
Vähimmäisturvaetäisyydet (mm)
Minimum Safety Distances (mm)
Kuva 2
Fig. 2
Tarkista ohjauskeskuksen tehonkesto
ohjauskeskuksen käyttöohjeesta.
Kontaktoriyksikkö tarvitaan, jos
kiukaan teho ylittää erillisen ohjaus-
keskuksen kapasiteetin.Erillinen kon-
taktoriyksikkö voidaan liittää kiukai-
siin joiden teho on 10,5kW tai
enemmän.
NOTE:
Please refer to the control unit
manual for maximum power rating.
Contactor unit is needed if heater’s
power rating exceeds separate
control unit’s capacity. Additional
contactor unit can be connected to
the heaters 10,5kW and higher.