26 SawStop 10” Industrial Cabinet Saw
Setting Up Your Saw
In addition, the disconnect switch can be locked in the OFF position with a padlock or similar device as shown
in Fig. 20. The disconnect switch should be locked in the OFF position whenever there is a possibility of
someone accidentally applying power to the saw while adjustments, maintenance or repairs are being made.
When the saw has been completely installed and is ready for use, turn the disconnect switch to ON as shown
in Fig. 21.
13. Access Door Interlock Switches:
As an additional safety feature, this saw is equipped with interlock
switches on the belt access door and the motor cover that prevent
the motor from starting when either door is open. In the event that
one of the doors is opened while the motor is on, the corresponding
interlock switch will cause the motor to shut down.
If either the access door or motor cover is open when you attempt
to start the motor (or if a door opens when the motor is already
on), a System Status error will be displayed where the red LED
is on solid and the green LED flashes rapidly . If this occurs, you
must close and latch the open door and then cycle the Main Power
switch on the Switch Box. (See page 28.)
The interlock switches are pre-positioned to be “closed” when the
belt access door and motor cover are fully closed. In the event
one of the switches becomes mis-aligned, you can reposition the
switch(es) as described below to ensure all switches are closed
when the access door and motor cover are closed.
WARNING!
The door interlock switches are connected to 208-240 VAC. Attempting to
disable or modify the interlock switches or wiring could result in a severe injury or electric
shock. Turn the Disconnect Switch to OFF before adjusting the interlock switches.
Fig. 22
Fig. 23
Cabinet Saw Manual 1st Reprint.i26 26
3/9/2010 8:32:48 AM