Instruction manual
75430, 75431, 75433, 75435, 75440, 75442, 94793
Palin LED PIR Wall
Saxby Lighting. BH17 7BY
V2 23/10/2020
For your safety, always switch off the power supply before changing lightbulbs, adjusting spotlight heads or cleaning.
Care and Safety
PIR Adjustment
Do not use solvents or abrasive cleaners as these could damage the finish.
75430, 75433,
75440, 94793
75431, 75435,
75442
•
The unit must be installed in a vertical position, and fitted 1.8-2.5m above the ground.
•
The PIR sensor can be adjusted, allowing the detection
distance to be altered to suit the location. The detection
angle is set at 110º. The duration that lamp stays on can
also be altered from 5 seconds - 5 minutes. The LUX
rang is 10-2000 lux. Use a small screwdriver to adjust
the "TIME" and "SENS" screws. When adjusting the
sensitivity (detection distance) in daylight it will be
necessary to cover the sensor to simulate night time.
To access the adjustment screws flip down the black cover over the PIR sensor. Take great care when adjusting the
sensor screws not to over tighten as they can be easily broken.
POWER ON
AUTO MODE
MANUAL MODE
1
2
3
The PIR sensor has a manual override function which can be operated by taking the following steps:
•
When power on, the PIR detector enters into the “WARM-UP” periods for about 1 minute, then automatically change into
AUTO MODE.
•
During MANUAL MODE or AUTO MODE, by switching off the ON/OFF
main switch over 6 seconds and then on again, the PIR detector will
reset to WARM-UP. Please note: the period of “WARM-UP” maybe be
shorter than 1 minute.
•
During AUTO MODE, by switching the ON/OFF main switch for 2 times within 3 seconds then switch on, the PIR detector will
automatically change to MANUAL MODE. In MANUAL MODE, the Lamp(s) will remain ON, in MANUAL MODE the PIR
detector is not affected by duration time and Lux control level.
For
75430
and
75431
, in normal circumstances, stainless steel is very resistant to corrosion. It does however require
maintenance to preserve the high quality appearance. Wash the product with warm soapy water, removing all surface
deposits. Rinse with clear water and with a soft cloth, wipe dry.
In some cases, surface corrosion may arise after installation. This is normally caused by tiny iron particles left behind after
the brushing process when finishing.
Wash and dry as detailed above. Then with a soft cloth soaked with a protective oil, wipe all over. However if the
product is subject to extreme environmental conditions such as marine locations, industrial pollution and acid rain these
maintenance procedures should be carried out around four times a year. For severe corrosion, non-abrasive cream
cleaners or proprietary stainless steel cleaners should be used to remove the corrosion. Wash and dry as detailed above.
Then with a soft cloth soaked with a protective oil, wipe all over.
Do not clean the units with a pressure washer.
Adjustable up to 8 metres
PIR Adjustment
1.8- 2.5Metres
4M
6M
8M
appro. 110º