Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and
satisfactory operation of this product. Please retain these instructions for future reference.
Warning
This is a Class 1 product and must be earthed.
Please read these instructions carefully before
commencing any work.
This unit must be fitted by a competent and qualified
electrician.
Install in accordance with IEE Wiring regulations and
current Building Regulations.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting. Ensure
other persons cannot restore the electrical supply
without your knowledge.
This light fitting should be connected to a fused circuit.
If replacing an existing fitting, make a careful note of
the connections.
Always use the correct type and wattage bulb. Never
exceed the wattage stated.
When changing a bulb, always switch off at the mains
and allow the old bulb to cool down before handling.
Dispose of used bulbs carefully and responsibly.
This product is suitable for dimming when used in
conjunction with a dimmable lamp. Please ensure
verification of dimming abilities with the lamp
manufacture prior to use.
Waste electrical products should not be disposed of
with household waste. Please recycle where facilities
exist. Check with your local authority or retailer for
recycling advice.
Specification
Voltage:
240V 50Hz a.c.
Lamp:
1 x Max. 18W G9 Halogen
IP rating:
44
Layout
Installation
Wiring
Having correctly identified the wiring from your existing
light fitting, pull the wire through the hole and connect to
the connection block inside the product in the following
way:
Check that...
• You have correctly identified the wires
•
The connections are tight
• No loose strands have been left out of the connection
block.
OUTSIDE ZONES
ZONE
2
ZONE
1
0.6m
0.6m
2.25m
Ceiling
Spotlights give a concentrated beam
of light and must not be positioned
any closer than 0.3M (30cm) to the
illuminated surface.
This product is suitable for use in Zone
2 and outside Zones of a bathroom.
See diagram. If this unit is being
fitted in a room containing a bath or
shower, a 30mA RCD must be used,
in accordance with IEE regulations.
• Plan the desired layout of this fitting carefully,
ensuring the cables will reach the distance between
the junction box and the light fitting
• Avoid locating any cables in positions that would
cause a hazard. Position cables and junction boxes
(not supplied) away from areas where they may be
at risk from being cut, trapped or damaged
• The mains supply cable must have a minimum cross
sectional area of 1.0mm²
• This product must be mounted out of arms reach.
• This product has special protection against the
ingress of moisture and is IP44 rated.
Existing fittings must be completely removed before
installation of a new product. Before removing the
existing fitting,
carefully note the position of each set
of wires
.
• Undo the screws holding the fixing bracket in place
and set aside
• Hold the product in place and mark the position of the
holes.
• Ensure the ceiling is capable of holding the weight
of the product. Take care to avoid damaging any
concealed wiring and pipes.The correct fixings should
be used. Ensure there is a joist at the point of fixing to
support the weight of the product.
• Fix the ceiling bracket into position.
NEUTRAL
EARTH (GREEN/YELLOW)
SWITCHED LIVE
BLUE (N)
GREEN/YELLOW
BROWN (L)
SUPPLY
LIGHT FITTING
4th BLOCK PROVIDED FOR LOOP
TERMINATION IF NECESSARY