background image

 

‐ 

8

 ‐ 

868.42

 

MHz

 

   

China

 

/

 

Europe

 

908.42

 

MHz

 

 

United

 

States

 

921.42

 

MHz

 

   

Australia

 

Operating

 

frequency

 

869.22

 

MHz

 

 

Russia

 

from

 

the

 

indoor

 

distance

 

of

 

30

 

meters

 

The

 

distance

 

Outdoor

 

straight

 

distance

 

of

 

40

 

meters

 

Operating

 

temperature:

 

10

℃~

+50

 

Relative

 

humidity

 

95

RH

 

 
 

z

 

Z

Wave

 

Parameters

 

Device

 

Type:

 

Generic

 

Deice

 

Type

 

=

 

GENERIC_TYPE_GENERIC_CONTROLLER

 

Specific

 

Device

 

Type

 

=

 

SPECIFIC_TYPE_PORTABLE_REMOTE_CONTROLLER

 

 

Support

 

Command

 

Class:

 

COMMAND_CLASS_ZWAVEPLUS_INFO,

 

COMMAND_CLASS_VERSION,

 

COMMAND_CLASS_WAKE_UP,

 

COMMAND_CLASS_SECURITY,

   

COMMAND_CLASS_MANUFACTURER_SPECIFIC,

 

COMMAND_CLASS_POWERLEVEL,

 

COMMAND_CLASS_DEVICE_RESET_LOCALLY,

 

COMMAND_CLASS_ASSOCIATION,

 

COMMAND_CLASS_ASSOCIATION_GRP_INFO,

 

COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION,

   

COMMAND_CLASS_BATTERY,

 

COMMAND_CLASS_APPLICATION_STATUS,

 

COMMAND_CLASS_NOTIFICATION,

 

COMMAND_CLASS_CENTRAL_SCENE,

 

COMMAND_CLASS_PROTECTION

 

Summary of Contents for Key-fob

Page 1: ...o master controller and it can associated control devices by key fob local operation or master controller association set configuration The product is Z Wave wireless accessible and it can quickly easily included and operated in any Z Wave network with other Z Wave certified devices from any other manufacturers All non battery operated nodes within the network will act as repeaters regardless of v...

Page 2: ...iated from GUI of the master controller Secure vs no Secure add to Z Wave Network The production is a security enabled Z wave Plus production implements Z Wave Application Security Layer in accordance with Z Wave protocol This device must be used in conjunction with a Security Enabled Z Wave Controller in order to fully implemented secure functions Even though the functionality and support command...

Page 3: ... Function Description LED indicator Press and hold for 2 sec Illumine 1 Reset Factory Default Press and hold for 10 sec Blink off 0 5sec interval 2 second while hold until flash on 3 times Press and hold for 2 sec Illumine 2 Wakeup key fob manually and send battery report to lifeline group 1 Press 3 times in 2 sec Flash on fast 3 times then keep in wakeup for 30 second w o initial wakeup parameter...

Page 4: ...rotected Press or hold any key Blink on 3 times 0 5 second on 0 5 second off Note Item 1 2 15 16 is available while key fob in Idle state item 3 4 is available as key fob is primary or installer controller Item 5 is available as key fob is primary controller only item 6 is available as key fob hasn t add any node item 9 11 is available in anytime item 7 8 12 14 is available as key fob was added in...

Page 5: ...ce procedure Remove Z Wave Device from key fob 1 Press and hold both and key together for 2 seconds until LED indicator light on release all key 2 Press and hold key for 2 seconds until LED indicator flash quickly 1 second on 1 second off key fob starts remove device processing 3 Refer to device manual trigger the device which is going to included start network add remove mode 4 If key fob detects...

Page 6: ... if there not any controller was detected Note Key fob s learn mode is only available as it has not added any device before or has included in master controller already Key fob always ignores Basic Set Get command requires from other controller Note Press and hold on key for 2 seconds after step 3 would terminal procedure if Z Wave adding processing has not started Remove key fob from other Z Wave...

Page 7: ...vice from group 2 4 together and LED indicator light on for 3 seconds after delete association successful If key fob has not detects any device in 60 seconds exit delete associated device process and LED indicator goes off Note Key fob s delete associated locally function is only available as it was included in other master controller Key fob always deletes the associated device with endpoint toge...

Page 8: ...C_CONTROLLER Specific Device Type SPECIFIC_TYPE_PORTABLE_REMOTE_CONTROLLER Support Command Class COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_VERSION COMMAND_CLASS_WAKE_UP COMMAND_CLASS_SECURITY COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION COMMAND_CL...

Reviews: