background image

10

Splitz-it  5-tON electric lOg Spliter

ORDERING REpAIR pARTS

Parts can be obtained from the store where your mini log 

splitter was purchased.
Please include the following information with your order:
1.  Part numbers
2.  Part description
3. Quantity
4.  Model number and serial number

SERVICE INFORMATION

In the event you experience trouble operating your log splitter, 

follow the suggestions in the troubleshooting guide in this 

section.
The guide will help you pinpoint the causes of common 

problems and identify remedies.
We will always be glad to answer any questions you have, 

or help you find suitable assistance. To order parts or inquire 

about warranty, see the section ordering repair parts.

SERVICE, TROUbLESHOOTING AND REpAIR

TROUbLESHOOTING

IMpORTANT

IN CASE OF A SERVICE pRObLEM, DO NOT SEND UNIT 

bACk TO RETAILER. 

CONTACT SbI HEATING ACCESSORIES, 
TELEpHONE: 1 418  878-3040  
E-MAIL: tech@sbi-international.com

pRObLEM

pOSSIbLE CAUSE

REMEDY/ACTION

Fails to split logs

1. Log is improperly positioned

1. Refer to Log Splitter Operation Section for log 

loading

2. The size or hardness of the log exceeds 

the capacity of the machine

2. Reduce the log size before splitting on the log 

splitter

3. Wedge cutting edge is blunt

3. Refer to Sharpening Wedge Section to sharpen 

the cutting edge

4. Oil leaks

4. Locate leak(s) and contact the dealer

5.  Unauthorized adjustment was made onto 

the maximum pressure limiting screw

5. Contact the dealer

The log pusher moves with 

a jerking motion, makes an 

unfamiliar noise or vibrates 

excessively

1. Lack of hydraulic oil and excessive air in 

the hydraulic system

1.  Check oil level for possible oil refilling. Contact 

the dealer.

Oil leak occurs around cylinder 

ram or from other points

1. Air sealed in hydraulic system while 

operating

1. Loosen bleed screw 3-4 rotations before 

operating the log splitter

2. Bleed screw is not tightened before 

moving the log splitter

2. Tighten the bleed screw before moving the 

log splitter

3. Oil drain bolt with dipstick is not tight

3. Tighten the oil drain bolt with dipstick

4. Hydraulic control valve assembly and/

or seal(s) worn

4. Contact the retailer

contact service provider if above remedies fail.

Summary of Contents for AC02585

Page 1: ...WRITTEN CONSENT AND SHALL BE IMMEDIATELY RETURNED UPON REQUEST MATERIAL TOLERANCE UNLESS OTHERWISE NOTED 0 0 100 INCH 2 54 MM 0 00 030 INCH 0 76 MM NAME THIRD ANGLE PROJECTION SEE BILL OF MATERIALS W...

Page 2: ...Specifications Electrical Requirements 5 Set Up and Pre Operation 6 Assembly 7 Operation 8 Maintenance 9 Service Troubleshooting and Repair 10 Parts Explosion Breakdown and Parts List 11 12 Warranty...

Page 3: ...ving parts Always wear safety goggles for eye protection Everyday glasses have only impact resistant lenses and are not effective safety glasses Warning Warning INDICATES A HAZARD WHICH IF NOT AVOIDED...

Page 4: ...ual and the safety instructions it contains will provide you with the necessary knowledge to operate this equipment safely and effectively We have placed a safety de cal on the log splitter to remind...

Page 5: ...Force 5 ton Hydraulic Pressure 2 300 psi Hydraulic Oil Capacity 3 75 quarts Overall Size Length 37 inches Width 11 inches Height 20 inches Weight 105 lb The diameter of the log is not indicative a sm...

Page 6: ...r 6 Rubber feet 11 Log cradle 7 Rolling wheel Warning For your own safety do not connect the log splittertothepowersourceuntilthemachine is completely assembled and you read and understand the entire...

Page 7: ...op of the rolling wheel bracket with M6 1 x 12 bolts provided SEE FIGURE 3 4 Assemble the handle bars to the handle then attache the completed handle bar assembly to the log splitter beam using the M6...

Page 8: ...1 Release both controls 2 Once the log pusher completely stops at its starting position insert a wood wedge under the jammed log SEE FIGURE 7 3 Start the log splitter to push the wood wedge under the...

Page 9: ...back into the oil tank 7 Make sure the level of the refilled oil is between the two grooves around the dipstick 8 Clean the oil drain bolt before re threading it back in Make sure the bolt is tighten...

Page 10: ...properly positioned 1 Refer to Log Splitter Operation Section for log loading 2 The size or hardness of the log exceeds the capacity of the machine 2 Reduce the log size before splitting on the log sp...

Page 11: ...SPLITZ IT 5 TON ELECTRIC LOG SPLITER 11 SPLITZ IT 5 TON ELECTRIC LOG SPLITTER BREAKDOWN 17 18 9 10 11 12 27 25 26 29 13 8 7 14 15 16 6 5 4 3 1 2 28 20 19 22 23 21 24 30 31...

Page 12: ...le b w1200 1 14 w1200248 Control lever assy w1200 1 15 W1200122 WASHER M5 X 1 1 SPRLK HIGH COLLAR 2 16 W1200123 BOLT M5 8 X 16 SCH GR8 8 BLK OX F T 1 17 W120001 Motor assembly w1200 1 18 W1200207 Forw...

Page 13: ...supersede all other warranties either expressed or implied and all other obligations or liabilities on our part SBI Heating Accessories does not assume and does not authorize any other person to assum...

Page 14: ...______________________________________________________________________ _______________________________________________________________________________________________________ _________________________...

Page 15: ...______________________________________________________________________ _______________________________________________________________________________________________________ _________________________...

Page 16: ...sbI hEATING accessoRIes 250 rue de copenhague saint augustin de desmaures qu bec canada g3a 2h3 Tel 418 878 3040 FAx 418 878 3001 email info sbi international com...

Reviews: