29
COMMISSION REGULATION (EU) 2015/1188
Requirements for product information applicable to commercial local space heaters
Luminous heaters XFR
Model identifier
XFR
16
XFR
20
XFR
20-2
XFR
24
XFR
24-2
XFR
32
XFR
32-2
XFR
48-2
XFR
64-2
Type of heating
Luminous heaters
Fuel
Gaseous
Space heating emissions
NO
x
emissions (mg/kWh
PCS
)
< 50
Heat input
Nominal heat input (kW
PCS
)
6,4
7,4
7,4
8,9
8,9
11,4
11,4
17,8
22,9
Minimum heat input (kW
PCS
)
n.d
n.d
3,7
n.d
4,45
n.d
5,7
8,9
11,45
Minimum heat input (% of P
nom
)
n.d
n.d
50
n.d
50
n.d
50
50
50
Radiant factor
Radiant factor at nominal heat output
0,77
0,85
0,85
0,82
0,82
0,77
0,77
0,82
0,77
Radiant factor at minimum heat output
0,77
0,85
0,85
0,82
0,82
0,77
0,77
0,82
0,77
Auxiliary electricity consumption
At nominal heat input (kW)
0
0
0
0
0
0
0
0
0
At minimum heat input (kW)
0
0
0
0
0
0
0
0
0
In standby mode (kW)
0
0
0
0
0
0
0
0
0
Heat output control type
Single stage
Yes
Yes
No
Yes
No
Yes
No
No
No
Two stages
No
No
Yes
No
Yes
No
Yes
Yes
Yes
Modulating
No
No
No
No
No
No
No
No
No
Seasonnal efficiency
Seasonnal space heating efficiency
92,3 % 95,7 % 98,2 % 94,4 % 96,9 % 92,3 % 94,8 % 96,9 % 94,8 %