background image

15 

 Meter displays VOLTAGE WARNING regardless of AUTO or MANUAL measurement.    When 

over the Maximum Measurement limit, the WARNING sound starts. At this case, immediately 
remove Test Lead/Test Probe from the Meter. 

 When measurement range set manually. If the measurement exceeds the range, the display 

will show 

“OL”.

 

 

Power 

 6*AA    Alkaline Battery ( 

SBS-600

 only ) 

 7.2V NiMH Battery Pack or AC Power Adapter ( 

SBS-700

 only ) 

 

Remaining Battery Capacity Level indicator   

 Top right display indicates Remaining Battery Capacity Level, 

Level 

Remaining Battery 

Fully Charged. 

(100%) 

3/4 charged 

(75 %) 

1/2 charged

(50 %) 

1/4 charged 

(25 %) 

Depleted 

( 0 %) 

 

Auto Power Off 

 During operation the unit will automatically power off after 15 minutes without a button push. 

 User can select the Auto Power Off time (min 5 minutes ~ max 2 hours or Auto Power Off 

mode). 

[NOTE] 

   Auto Power Off mode is not active in DATA LOGGER mode (MIN MAX, PEAK mode in 

operation)   

 

 

Auto Power Off mode is not active when the Meter is powered by ADC Power Adaptor 

(

SBS-700 only

 

Battery Save Mode   

 Auto Power Off mode is not activated during Data Logger or Auto Hold mode of operation. If 

no key is pressed on Meter for a certain time, Meter automatically changes to Battery Save 

Mode. Mode Change time is equal to Auto Power Off mode time setting. 

 All Power off including Display, except present measurement function.     

 Exit the Battery Save Mode by 

- Pressing any key 

- change measurement range     

- start PC Interface communication. 

     

Meter function and Operation Mode is not changed 

Summary of Contents for SBS-600

Page 1: ...Multi Function Oscilloscope Quick Start Guide Quick start guide will explain basic information about the unit For complete Operation and Safety Information Please refer to the 99 Washington Street Mel...

Page 2: ...rect Current or Voltage AC Alternating Current or Voltage DC and AC Earth Ground Double Insulation Power Supply OFF Power Supply ON Warning of Electric Shock Warning of Danger Category 1000V Overload...

Page 3: ...ttery Warning Symbol is blinking on the display the measurement may display in error Recharge the battery or replace Observe all terminal ratings Observe all rating and marking oin the Meter Refer to...

Page 4: ...al and Electronic Equipment 2002 96 EC Meter complies with WEEE 2002 96 EC requirements Do not dispose Electric Electronics device with other trash Front View Key Pad The Keys are different by models...

Page 5: ...ly select the Function or Menu Voltage measurement keys AC DC DC AC Current measurement keys AC DC DC AC Resistance Continuity Diode Check key Capacitance measurement key Auxiliary measurements Temper...

Page 6: ...To return to Auto measurement mode hold key down longer than 2 seconds Upper Line Short Key One Touch press enter Data Logger mode Lower Line Long key Hold longer than 2 seconds to enter Save Data an...

Page 7: ...tection selection ON OFF 8 V Position Volt Vertical Axis Position adjustment 9 T Position Time Horizontal Axis Position adjustment 10 Trig Level Trigger Level adjustment I Help Short Key One Touch pre...

Page 8: ...ar Graph refer details Bar Graph page 7 Compare with a reference value and display the Difference 8 Negative Reading 9 Input Over Voltage warning that exceeds the defined safety protection voltage 10...

Page 9: ...le Q ty in Data Logger 5 Maximum Display Range 6 Minimum Maximum Average of the Samples 7 Total Time Scale of Data Logging 8 Present Measurement Value 9 Change the Time Scale left right horizontal axi...

Page 10: ...DMX512 1 Wire 2 Time div Measurement Time div Indicator 3 Channels Displays all the Input Channels 4 Horizontal Time Division Position adjustment 5 Trigger Trigger Mode Source and Trigger Level adjus...

Page 11: ...6 Message Used for making the format cycle and data of each pattern 7 Output Selection of signal out or not 8 Information Display window to show the information of In Out Transaction or all the memori...

Page 12: ...AX and is displayed at RIGHT of BAR GRAPH at positive MAX Measurement Status display Status icon is displayed at top of Display Battery status Present Measurement Value Buzzer Continuity Data Hold Aut...

Page 13: ...OM Negative Terminal to all measurements SCOPE V Sig out Volts Continuity Resistance Diode Capacitance Frequency measurement and AUX auxiliary function with external adapter Temperature High Current R...

Page 14: ...Input model SBS 700 max 300V Other Multi meter function Input models SBS 600 SBS 700 max 600V Pin No Function Pin No Function 1 Ground Black Clip 9 Ground Black Hook 2 Signal out Red Clip 10 N A 3 N...

Page 15: ...the unit will automatically power off after 15 minutes without a button push User can select the Auto Power Off time min 5 minutes max 2 hours or Auto Power Off mode NOTE Auto Power Off mode is not ac...

Page 16: ...h press each step Up Down MENU After main function DSO is selected press MAIN Menu to select Channel Trigger Measure Cursor After Main Menu selected Select Sub Menu F1 F2 F3 F4 to proceed to desired m...

Page 17: ...rer Connect the Battery with the proper polarity When charging the battery use only the AC Adapter and Internal charger supplied from the original manufacturer Please follow Battery Charging procedure...

Reviews: