17 

[Note] 

 Model   

SBS-600

 uses only 6 * AA, 1.5V Alkaline battery - Non Rechargeable Battery. 

    Model   

SBS-700

 uses only the supplied 7.2V NiMH Rechargeable Battery Pack.   

 When  Battery  low  signal  is  blinking,  In  the  model 

SBS-600

,  replace  with  New  AA  Alkaline 

battery cell as soon as possible. In the model 

SBS-700

, recharge the battery pack as soon as 

possible.     

 If Battery is completely depleted, and needs to be replace with a new battery, please replace 

battery using the following procedure. 

 Remove the Holster Case from the Meter. 

 Remove Battery Cover from the Rear Case of the meter. 

 Replace Battery and be sure to connect correct polarity inside the battery compartment. 

 Close  Battery  Cover  and  assembly  in  reverse  order  of  above  when  opening  Battery 

Compartment 

 

Battery Charge

 (model 

SBS-700

 only)

 Do not discharge battery with reverse polarity.   

 Do not use any other Rechargeable Battery. Use only the 7.2 V NiMH battery pack supplied 

from original manufacturer.   

 Connect the Battery with the proper polarity. 

When charging the battery, use only the AC Adapter and Internal charger supplied from the 
original manufacturer. 

 Please follow Battery Charging procedure. 

   Connect the DC Power adapter to Power Outlet.

   Plug charging connector into the 

SBS-700

.

   When Charging is completed, “FULLY CHARGED”

 

message is displayed on the screen.

   If Battery is fully charged, disconnect DC Power Adapter.

   Do not charge Battery while meter is being use

 

Fuse Replacement 

If the Fuses open due to fault, Replace fuses using the procedure below ; 

 Power off the Meter. Disconnect Test Lead from Meter. 

 If DC power adapter is connected, disconnect the adapter from the meter.   

 Separate Battery Cover from meter.   

 Pull out one end of defect Fuse from Fuse Clip.   

 Replace with same size and rating Fuse. Fuse should be placed in center of Fuse Clip. 

 Do not touch any other component besides Fuse.   

 Assemble the Battery Cover to the meter   

 Fuse Ratings and Dimensions are as below ; 

[Fuse Rating and Dimensions] 

 500mA/250V  5mm × 20mm    (FF) 

 1OA/250V

     

6.3mm × 32mm    (FF) 

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com 

Summary of Contents for SBS-600

Page 1: ...Multi Function Oscilloscope Quick Start Guide Quick start guide will explain basic information about the unit For complete Operation and Safety Information Please refer to the 99 Washington Street Mel...

Page 2: ...rect Current or Voltage AC Alternating Current or Voltage DC and AC Earth Ground Double Insulation Power Supply OFF Power Supply ON Warning of Electric Shock Warning of Danger Category 1000V Overload...

Page 3: ...ttery Warning Symbol is blinking on the display the measurement may display in error Recharge the battery or replace Observe all terminal ratings Observe all rating and marking oin the Meter Refer to...

Page 4: ...al and Electronic Equipment 2002 96 EC Meter complies with WEEE 2002 96 EC requirements Do not dispose Electric Electronics device with other trash Front View Key Pad The Keys are different by models...

Page 5: ...ly select the Function or Menu Voltage measurement keys AC DC DC AC Current measurement keys AC DC DC AC Resistance Continuity Diode Check key Capacitance measurement key Auxiliary measurements Temper...

Page 6: ...To return to Auto measurement mode hold key down longer than 2 seconds Upper Line Short Key One Touch press enter Data Logger mode Lower Line Long key Hold longer than 2 seconds to enter Save Data an...

Page 7: ...tection selection ON OFF 8 V Position Volt Vertical Axis Position adjustment 9 T Position Time Horizontal Axis Position adjustment 10 Trig Level Trigger Level adjustment I Help Short Key One Touch pre...

Page 8: ...ar Graph refer details Bar Graph page 7 Compare with a reference value and display the Difference 8 Negative Reading 9 Input Over Voltage warning that exceeds the defined safety protection voltage 10...

Page 9: ...le Q ty in Data Logger 5 Maximum Display Range 6 Minimum Maximum Average of the Samples 7 Total Time Scale of Data Logging 8 Present Measurement Value 9 Change the Time Scale left right horizontal axi...

Page 10: ...DMX512 1 Wire 2 Time div Measurement Time div Indicator 3 Channels Displays all the Input Channels 4 Horizontal Time Division Position adjustment 5 Trigger Trigger Mode Source and Trigger Level adjus...

Page 11: ...6 Message Used for making the format cycle and data of each pattern 7 Output Selection of signal out or not 8 Information Display window to show the information of In Out Transaction or all the memori...

Page 12: ...AX and is displayed at RIGHT of BAR GRAPH at positive MAX Measurement Status display Status icon is displayed at top of Display Battery status Present Measurement Value Buzzer Continuity Data Hold Aut...

Page 13: ...OM Negative Terminal to all measurements SCOPE V Sig out Volts Continuity Resistance Diode Capacitance Frequency measurement and AUX auxiliary function with external adapter Temperature High Current R...

Page 14: ...Input model SBS 700 max 300V Other Multi meter function Input models SBS 600 SBS 700 max 600V Pin No Function Pin No Function 1 Ground Black Clip 9 Ground Black Hook 2 Signal out Red Clip 10 N A 3 N...

Page 15: ...the unit will automatically power off after 15 minutes without a button push User can select the Auto Power Off time min 5 minutes max 2 hours or Auto Power Off mode NOTE Auto Power Off mode is not ac...

Page 16: ...h press each step Up Down MENU After main function DSO is selected press MAIN Menu to select Channel Trigger Measure Cursor After Main Menu selected Select Sub Menu F1 F2 F3 F4 to proceed to desired m...

Page 17: ...rer Connect the Battery with the proper polarity When charging the battery use only the AC Adapter and Internal charger supplied from the original manufacturer Please follow Battery Charging procedure...

Reviews: