4
© 2011. Scaletron Industries Ltd. Plumsteadville, PA Scaletron. Scaletron Sets The Standard In Corrosion Resistance. Model 1099, Model 2305, Model
2306, Model 2307, Model 2308, Model 2310, Model 2330, Model 2350, Model 2352, Model 2353, Model 3001, Model 3002, Model 3003, Model 3004,
Model 3005, Model 3006, Model 4000SS, Model 4010, Model 4020, Model 4021, Model 4030, Model 4040, Model 4041, Model 4042 and Model 4042WB,
and Pro-Gram Guide are trademarks of Scaletron Industries Ltd. Total Electronic System is a service mark of Scaletron Industries Ltd. All Rights
Reserved. .PRINTED IN U.S.A. NOV 2011.
1.
If display reads: “-1”:
A.
Gross under-load. Turn knob clockwise. Numbers should reappear and can be
adjusted to tare weight or zero as required.
B.
Check load cell connections at indicator, and connect wires as per diagram on Page
5.
2. If display reads: “1”:
A.
Gross over-load. If starting point was zero, the cylinder weight is more than 199.9 lb.,
or kg.
B.
If starting point was
–150.0 lb. (68kg.) then the cylinder weight is more than 349.9 lb.
(158 kg.). Remove weight and recheck tare setting.
C.
Check load cell connections according to page 2.
3. If no display (not lit):
A.
Check power to weigh meter by pressing momentary switch button.
B.
Battery pack may need to be recharged. Connect battery pack to the charger (only as
supplied by Scaletron) and fully recharge the battery pack.
4. Other Problems:
A.
Consult the Factory!
USA & Canada Toll-Free: (800) 257-5911
Tel: (+1) 215-766-2670
Fax: (+1) 215-766-2672
Notice:
Do not return any equipment without first contacting the factory. A return authorization
number will be issued and it must be marked on all materials returned to the factory,
accompanying a letter that explains the problem specifically. A Serial Number will also be
required. It is located inside the indicator box.