background image

© 2007.  Scaletron Industries Ltd. Plumsteadville, PA  Scaletron.  Scaletron Sets The Standard In Corrosion Resistance.  Model 1099, Model 2305, Model 2306, Model 2307, Model 
2310, Model 2330, Model 2350, Model 2352, Model 2353, Model 3001, Model 3002, Model 3001 SI, Model 3002 DI, Model 3003, Model 3004, Model 3005, Model 3006, Model 3050-1, 
Model 3050-2, Model 4010, Model 4020, Model 4021, Model 4030, Model 4040,  Model 4042, Model 4042WB,Model 4041, Model 4042, Model 4042 WB, Model 5305, Model 5305-2, and 
ProGram Guide are trademarks of Scaletron Industries Ltd.  Total Electronic System is a service mark of Scaletron Industries Ltd.  All Rights Reserved.  .PRINTED IN U.S.A.  JULY 2007.

 

These instructions generally describe the installation, operation, and maintenance of subject 

equipment.  The manufacturer reserves the right to make engineering refinements that have not been 
described herein.   Should any questions arise that may not be answered specifically by these 
instructions, they should be directed to 

Scaletron Industries Ltd.

Or Our Sales Agent 

for a 

response. 

All possible precautions were taken in packaging each piece of equipment to prevent shipping 

damage.  Carefully inspect each item and report damages immediately.  Report all damage claims to 
the shipping agent involved for equipment shipped F.O.B. job site.  Do not install any damaged 
equipment. 

All instructions given on any labels, or attached tags, should be followed.  Carefully inspect all 

packing material before discarding to prevent the loss of accessories, mounting hardware, spare 
parts, or instructions. 
 

TABLE 

OF 

CONTENTS 

 

 

 

 

 

          PAGE 

 

I. GENERAL 

DESCRIPTION…………………………………………………………………………….1 

II.  SPECIFICATIONS…………………………………………………………………………………..1 - 2 

III. ASSEMBLY 

AND 

START-UP…………………………………………………………………………2 

IV.  GENERAL USE INSTRUCTIONS…………………………………………………………………….3 

V.  CALIBRATION PROCEEDURE………………………………………………………………..…3 - 4 

VI. TROUBLESHOOTING…………………………………………………………………………………4 

VII.  BOARD DIAGRAM…………………………………………………………………………………5 - 6 

 
I. General 

Description:

 

The Model 4042™ and 4042WB™ Secondary Spill Containment Scale is designed specifically 
with a built-in containment basin.  Off center loading or solid materials do not affect the scale 
accuracy due to the four cell design.  Mixers and pumps may be used with this base design.  
Different base sizes are available, as well as custom bases for different size platforms and 
large capacities.  The maximum net weight is 199.9 lb./ or kg. with 0.1 lb/ or kg resolution,  or 
with a maximum net weight exceeding 199.9, the decimal is blanked at the factory, and the 
display can read 1999 lb/ or kg. on the standard, 3 ½ Digit indicator. 
The design of the platform includes sturdy four point support, with a polyethylene containment 
basin.  The base is coated with dry polyester powder coating to prevent corrosion.  Scale has 
four temperature compensated strain gauge transducers.   

Standard Parts 
 

1 Base assembly 

 

1 Weigh Meter (indicator) 

1 Power Cord 

 

1 Technical Manual 

 

Available Options 
 

A.  Remote mounting of standard enclosure 
B.  Load Cell Cable 
C.  Low Level relay contact 
 

II. Specifications:

 

Display:

  LCD, 3 ½ Digit with minus sign liquid crystal display, 0.5 inch high, seven segment 

Resolution:

  Tank: 199.9 lb x 0.1 lb, or 200 to 1999 lb.x 1.0 lb. 

Summary of Contents for 4042

Page 1: ...e P O Box 365 Plumsteadville PA 18949 USA Toll Free 1 800 257 5911 USA Canada Phone 1 215 766 2670 international Fax 1 215 766 2672 E mail info scaletronscales com Website www scaletronscales com OEM Manual MODEL 4042 AND 4042WB 3 DIGIT SECONDARY SPILL CONTAINMENT SCALE ...

Page 2: ...hould be followed Carefully inspect all packing material before discarding to prevent the loss of accessories mounting hardware spare parts or instructions TABLE OF CONTENTS PAGE I GENERAL DESCRIPTION 1 II SPECIFICATIONS 1 2 III ASSEMBLY AND START UP 2 IV GENERAL USE INSTRUCTIONS 3 V CALIBRATION PROCEEDURE 3 4 VI TROUBLESHOOTING 4 VII BOARD DIAGRAM 5 6 I General Description The Model 4042 and 4042...

Page 3: ...d inspect for damage bent metal broken wires cracks in indicator etc Any shipping damage must be reported to carrier Step 2 Place the scale on a solid dry and even surface Clear the area of all debris where the scale base will be placed VERY IMPORTANT If Model 4042WB make sure that expandable bladder has room and clearance to expand without coming into contact with any other objects that may cause...

Page 4: ...et Weight contents in the tank If this is the case you will use this procedure Load on your full tank and attach any equipment that affects the weight on the scale Turn the black tare knob on the front of the indicator until it reads the known NET WEIGHT weight of contents only on the indicator Clockwise will increase the readings and counter clockwise will decrease the readings When the weight is...

Page 5: ...5 Adjust tare knob on front of weigh meter until scale reads zero with no weight on platform Adjust R 22 to set the 4mA reading to 0lbs 6 Place a known weight on the disc as close to center as possible Weight should be equal to of capacity or greater 7 Adjust R 15 until display reads weight of test weight on scale disc 8 To complete calibration of 4 20mA output adjust R 19 for proper 20 mA adjustm...

Page 6: ... Model 3001 SI Model 3002 DI Model 3003 Model 3004 Model 3005 Model 3006 Model 3050 1 Model 3050 2 Model 4010 Model 4020 Model 4021 Model 4030 Model 4040 Model 4042 Model 4042WB Model 4041 Model 4042 Model 4042 WB Model 5305 Model 5305 2 and ProGram Guide are trademarks of Scaletron Industries Ltd Total Electronic System is a service mark of Scaletron Industries Ltd All Rights Reserved PRINTED IN ...

Page 7: ...02 Model 3001 SI Model 3002 DI Model 3003 Model 3004 Model 3005 Model 3006 Model 3050 1 Model 3050 2 Model 4010 Model 4020 Model 4021 Model 4030 Model 4040 Model 4042 Model 4042WB Model 4041 Model 4042 Model 4042 WB Model 5305 Model 5305 2 and ProGram Guide are trademarks of Scaletron Industries Ltd Total Electronic System is a service mark of Scaletron Industries Ltd All Rights Reserved PRINTED I...

Reviews: