WIRE LESS BAR CODE SCANNER
20
RS-232 Interface
Baud Rate
2400
4800
9600*
19200
38400
57600
Handshaking
None
:
Scan the bar code below if no Hardware Handshaking is desired
None
(
Default
)
Standard RTS/CTS
:
Scan the bar code below to select Standard RTS/CTS Hardware Handshaking.
Standard RTS/CTS
RTS/CTS Option 1:
When RTS/CTS Option 1 is selected, the scanner asserts RTS before transmitting and ignores
the state of CTS. The scanner de-asserts RTS when the transmission is complete.
RTS/CTS
Option 1
RTS/CTS Option 2:
When Option 2 is selected, RTS is always high or low (user-programmed logic level).
However, the scanner waits for CTS to be asserted before transmitting data. If CTS is not asserted within Host
Serial Response Time-out, the scanner issues an error indication and discards the data
RTS/CTS Option 2
Summary of Contents for SCWBS-1