13
Press ON/OFF key for three seconds to shut down the system and
the display screen will not show any more. Except ON/OFF key (B
key), other keys will stop responding, and compressor, door lamp
and other loads will be shut down immediately;
Press ON/OFF key for three seconds to start up the system. Be-
fore starting, if the system is at High Humidity Mode, the High
Humidity figure will shine, otherwise the system will only shine
the set temperature and all loads will run the mode having been
set before shutdown.
All following functions must be worked under start state.
High Humidity Mode
When the system is not at High Humidity Mode, press and hold Hi
Humidity key (A key) for three seconds to start the High Humidity
Mode and High Humidity figure will be lit up.
When the system is at High Humidity Mode, press and hold Hi
Humidity key (A key) for three seconds to exit from the High Hu-
midity Mode and High Humidity figure will not shine any more.
When starting High Humidity Mode, cooling chamber will work
under High Humidity state to improve relative humidity of the air
inside the cooling chamber.
Set the temperature of the cooling chamber
Press temperature regulation keys (C key) and (D key) to set the
temperature inside the chamber and the set temperature will
shine. The setting range is between 2 to 8 (non-periodic tem-
perature regulation); it will exit from the system in five seconds
and the setting will take effect. (within five seconds after finish-
ing the setting, press A key or B key to affirm the setting state
manually and make the setting valid.)
Illuminating lamp control
When open cooling chamber’s door, cooling chamber’s illuminat-
ing lamp will shine. When close cooling chamber’s door, cooling
chamber’s illuminating lamp will not shine any more.
Door-opening hint and door-opening alarming
control
When open the door, the music will ring for one time. If refrig-
erator chamber door has been open for 120 seconds, it will ring
warning bell, and the bell will ring per 2 seconds till the door is
closed. Press any key to cancel the door-opening warning.
Power-interruption memory and initial power-
up state
• When meet power interruption, the refrigerator can memory
operating mode and state before automatically; When
power up, it will recover to the state before interruption and
run the mode having been set before interruption.
• Initial power-up state: the set temperature of cooling cham-
ber is 5 and the system is not at High Humidity Mode.
• Memory: include set temperature of cooling chamber, ”High
Humidity” Mode and cumulative working hours of compres-
sor.
For example, if the system has a power failure under High Hu-
midity state, it will continue to work at ”High Humidity” mode
after recovery.
High temperature warning of the
refrigerating chamber
When the temperature of the cooling chamber has been above
15°C for six hours, high temperature warning will ring. The buzz-
er will ring per second for ten times and then ten times every
thirty minutes, and temperature display region will show failure
code (E9); the ringing will stop when the temperature of the
cooling chamber is below 10°C. Press any key to cancel the warn-
ing buzzer (if it does not buzz after thirty minutes). But the failure
code display state is not canceled, until the failure is solved.
Failure hint
Note: when there is a failure, the system will display all ma-
chine failures’ codes by turn. The warning will be automatically
canceled after recovery of the failure or press any key to cancel
the warning. When failure happens, it is a priority to show failure
code till failure recovery, otherwise the set temperature and High
Humidity state cannot be displayed.
If a failure has been displayed all the time and automatic recov-
ery fails, please contact After-sale Department or professional
maintenance personnel.
Force defrosting
Press and hold ”temperature regulation” keys and for three sec-
onds to enter into Force Defrosting Mode. High position of LED
temperature region always shows ”3” with no display in the low
position. When entering into Force Defrosting Mode, the com-
pressor will be stopped immediately. When working under Force
Defrosting Mode or the exiting condition is satisfied, press and
hold ”temperature regulation” keys and for three seconds to exit
form the Force Defrosting Mode.
Matters needing attention
Do not arbitrarily dismantle or repair. Choose the repair shops
designated by the manufacturer to replace the accessories.
Use standard professional three-hole power socket (above 10A).
Socket grounding must be good.
In order to avoid fire, please do not use combustible solvents
nearby the refrigerator. Pesticide
In order to avoid destroy, fire and other accidents, please do not
put anything combustible, explosive, volatile and strongly corro-
sive into the refrigerator. In order to avoid freezing, rupture and
other losses, please do not put the bottles with fluids or sealing
containers into the refrigerating box.
In order to avoid accidental harm caused by closing a child inside
or refrigerator falling, do not allow the children to enter into or
climb the refrigerator.
Do not put the heavy things on the refrigerator, otherwise it will
easily fall and cause harm.
Do not put too much food into the refrigerator.
Do not open the door and drawers for a long time or frequently
open the door and drawers, otherwise it would weaken the ef-
ficiency of the complete machine and increase operating load.
When the refrigerator is not at normal operation or is destroyed,
please cut off the power and inform local service center.