Summary of Contents for ARMOUR SLAU-UV-NB Series

Page 1: ...operator to harmful radiation and may void the user s authority to operate the equipment The SCAN LINK Armour System is to be used only as a tool to assist a vehicle operator and does not replace any...

Page 2: ...ces and policies to further inhibit the chances of worker injuries and fatalities Remember pedestrians will not be detected if they are not wearing functioning SCAN LINK tagged safety wear All employe...

Page 3: ...m Quick Start Guide 1_4 CONTENTS REQUIREMENTS STEP ONE MOUNT PAGE 7 STEP TWO WIRE PAGE 10 STEP THREE TEST PAGE 13 STEP FOUR REGISTER PAGE 15 SPECIFICATIONS PAGE 16 HOOK UP DIAGRAMS PAGE 18 LIMITED WAR...

Page 4: ...al device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This e...

Page 5: ...ntes dos condiciones 1 es posible que este equipo o dispositivo no cause interferencia perjudicial y 2 este equipo o dispositivo debe aceptar cualquier interferencia incluyendo la que pueda causar su...

Page 6: ...U UV NB XXX XX 04 Additions included in SLAU UV NB XX XX 04 KIT SERIAL NUMBERS MACs Write these down now before installing Antenna 00 1C 2C XX XX XX XX XX Display 00 1C 2C XX XX XX XX XX DISPLAY UNIT...

Page 7: ...ove this level will negatively affect the range of detection Choose a mounting location on your machine with 15 vertical and 10 horizontal clearance 40cm vertical 25cm horizontal The detection area is...

Page 8: ...o that it aims at a target five feet 150 cm off of the ground at a distance of 20 feet 6m Tighten down the pivot bolts so that the unit does not move Display Mounting The Display unit comes in a white...

Page 9: ...tenna Mounting Bracket The bracket has mounting holes on either side for the alarm Simply unthread the washer from the alarm insert the alarm into the mounting hole and thread the washer back on Use a...

Page 10: ...WG 1 02mm or larger wire Red Wire Power Supply Always VCC 12 28VDC Black Wire Power Supply Always VDD Equipment Ground Orange Wire Reverse Input Always Reverse Input Blue Wire Fault Relay Fault No Pow...

Page 11: ...you ve got the right one The Power Harness wires may be extended with 18AWG 1 02mm or larger wire Ensure that you weatherproof exterior connections or splices RED WIRE 12 24VDC fused 1A BLACK WIRE Gro...

Page 12: ...internally however this will not protect the wire or vehicle if the wire were to short against the frame of the vehicle and so fusing at 1A is strongly recommended At this point you can connect the Po...

Page 13: ...ll need to put the vehicle in reverse Stand approximately 30 feet 10 meters away from the Antenna and slowly walk towards the vehicle When within 20 feet of the vehicle the Display unit should alarm a...

Page 14: ...ree seconds Test one more time If you have to stand closer than 16 4 feet 5 meters to the vehicle it s possible that you need to adjust your aim either up or down Now standing far off to one side repe...

Page 15: ...em is warranted for one year If for whatever reason you need to return it to us you ll need to have a registered warranty It only takes a couple of minutes and is done online Head over to http www sca...

Page 16: ...connected to ground will be interpreted as the vehicle not in reverse Longitudinal Range 6 8m Typical Temperature Range 20 C to 50 C Ambient Cold temperature version available RFID Sensor Radio Freque...

Page 17: ...when connected to ground will be interpreted as the vehicle not in reverse Wireless Link Frequency 2 405 2 475 GHz North American unlicensed band Industry Canada ID 7084A SM220 Registered under Synaps...

Page 18: ...18 Armour System Quick Start Guide 1_4 Hook Up Diagram Reverse Trigger...

Page 19: ...19 Armour System Quick Start Guide 1_4 Hook Up Diagram Ignition Trigger...

Page 20: ...LINK repairs or replaces the Device during the Warranty Period the Warranty Period for the repaired or replaced Device will expire upon the expiration of the original Warranty Period Moreover the tim...

Page 21: ...ranty Exclusions and Limitations 14 As determined solely by SCAN LINK the Limited Warranty does not apply in situations where damage malfunction or defect to the Device is caused by or results from i...

Page 22: ...h SCAN LINK for loss or damage arising under this Limited Warranty shall not exceed in aggregate the price paid by the Purchaser for the Device or the cost of replacing the Device whichever is greater...

Page 23: ...TO Yellow Safety Vest Sizes Small Medium Large XLarge XXLarge SLYV14S SLYV14M SLYV14L SLYV14XL SLYV14XXL Orange Safety Vest Sizes Large SLOV15L Hard Hat Kit SLHHK External Beeper Alarm SLBA 12B RapidP...

Page 24: ...ide 1_4 SCAN LINK Technologies Inc 611 Tradewind Drive Unit 200 Ancaster Ontario L9G 4V5 Canada 905 304 6100 www scan link com GENERAL INFORMATION info scan link com SALES sales scan link com TECHNICA...