M O U N T I N G I N S T R U C T I O N S
6
If the steel chimney is installed directly on top of the stove,
we recommend the use of a connection piece/adaptor fitting
into the inside of the stove's flue collar to lead condensation
and rain into the stove, instead of on the top plate. A wrong
choice of length or dimension of the chimney can cause a
malfunctioning of the stove.
The diameter of the flue collar appears from the specific
instructions delivered with your stove.
Mounting of the flue collar with intermediate
ring (fig. 4).
Mount the flue collar with the intermediate ring in the flue
outlet of the stove using the special angle-fittings and long
screws in the service bag. At the same time, you can mount
the safety fitting in order to prevent the chimney sweep's
tools from destroying the ceramic smoke deflector.
Mounting of the flue collar without interme-
diate ring (fig. 5).
Mount the flue collar in the flue outlet of the stove using the
special angle-fittings and short screws in the service bag.
At the same time, you can mount the safety fitting in order
to prevent the chimney sweep's tools from destroying the
ceramic smoke deflector.
Mounting of the flue collar with safety fitting
(fig. 6).
Mount the flue collar in the flue outlet of the stove using the
special transversal fitting in the service bag. The safety fit-
ting's function is to prevent the chimney sweep's tools from
destroying the ceramic smoke deflector.
Scan 60 and Scan 61:
We refer to the specific instructions for these stoves.
Read carefully the instructions from the chimney manu-
facturer before beginning the mounting.
Fig. 4
Fig. 5
Fig. 6
Top discharge with direct connection to steel chimney