A
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 64\90064036.idw
90064036
Brændkammerforing
13-07-11
BC
Scan 64
VÆGT:
AREAL:
N/A
N/A
A
B
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 64\90064037.idw
90064037
Spjæld, askeskuffe og støbejernsbund
30-08-12
BC
Scan 64
VÆGT:
AREAL:
N/A
N/A
A
B
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 64\90064037.idw
90064037
Spjæld, askeskuffe og støbejernsbund
30-08-12
BC
Scan 64
VÆGT:
AREAL:
N/A
N/A
0%-100%
100%-0%
20
21
Baffle plates
The baffle plates are located in the upper part of the combustion
chamber. The plates hold back smoke, making sure it stays inside the
combustion chamber for a longer time before escaping through the
chimney. This reduces the flue gas temperature as the gases have
more time to dissipate heat to the stove. The baffle plates must be
removed for sweeping; see “Maintaining your wood-burning stove”.
Note that the baffle plates are made of porous, ceramic material, and
are liable to break easily. You should therefore handle them with care.
The baffle plates are subject to wear and tear and not covered by the
warranty.
Ash container
Open the door of the stove to access the ash container under the
combustion chamber.
The ash container must always be closed during operation.
The ash container must not be become too full and must therefore be
emptied at regular intervals.
Handle for riddling grate
The stove is equipped with a riddling grate that empties ash from the
combustion chamber down into the ash container when activated.
The riddling grate must remain half open while the wood stove is lit.
Primary air
Secondary air
Handle for riddling grate
Ash drawer
Adjustment of air supply,
primary and secondary damper
CB-technique
Baffle plates
I N ST R U C T I O N S F O R U S E
IMPORTANT!
This screw (M5X6) must
be placed as shown in the
picture,to prevent secondary
air control closure beyond the
35mm open position .
A
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
C:\Working Folder\CAD\Inventor 2015\Templates\Standard - Manual.idw
90064053
Skrue til england
24-03-2015
hms
Scan 64
VÆGT:
AREAL:
N/A
N/A
A
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
C:\Working Folder\CAD\Inventor 2015\Templates\Standard - Manual.idw
90064053
Skrue til england
24-03-2015
hms
Scan 64
VÆGT:
AREAL:
N/A
N/A
NAV
N:
STI
:
DIM
ENS
IO
N:
MAT
ERI
ALE
:
DAT
O:
SIG
N:
Sca
n A
/S
DK-
549
2 V
iss
enb
jer
g©
TG
.NR
:
EM
NE:
C:\W
ork
ing
Fo
lde
r\D
esig
ns\B
ygn
ing
sde
le\
Unb
rak
o 4
mm
.ip
t
Plad
e, s
t. 2
40
Unb
rak
o 4
mm
27-
04-
200
7
BC
VÆ
GT:
ARE
AL:
N/A
N/A
CB technology (Clean Burn)
The stove is equipped with CB technology. In order to ensure optimal
combustion of gases released during the combustion process, air pas-
ses through a specially developed system of channels. The heated air
is conducted into the combustion chamber through the holes in the
rear lining of the combustion chamber and at the baffle plates. This
airflow is driven by the combustion rate and cannot be regulated.
NOTE:
Wood must never be added above the CB rail.
Primary air
The primary air regulation mechanism is used for lighting the fire,
or to boost the burning process when you put wood on. The primary
air vent is used when you use hard wood fuel such as oak and beech.
The primary air vent can be closed if you use soft wood such as birch
or pine for fuel.
Settings for normal load: 0-30%
Settings for normal load: 50-70%
Secondary air
Secondary air is pre-heated and fed indirectly to the fire. At the same
time, the secondary airflow cleans the glass pane to prevent build-up
of soot. If you over-restrict the secondary airflow, soot can build up
on the glass pane. The secondary airflow determines the heat output
from your stove.