Adjustment of the handle
If the handle is not in the vertical position, you
can adjust as follows: loosen the screw (see
illustration), put the handle in the vertical posi-
tion and tighten the screw.
Handle
The door is opened by turning the handle
counter-clockwise.
Self-closing door (BA 1)
The door is prepared with a self-closing function at the fac-
tory. If you tighten the spring with the hexagon spanner, the
door will close automatically when you let go of it.
Accessories
For this model you can have the following accessories:
• Large grill
• Steel floor plate
SCAN 4
Stove
model
SCAN
Connecting
adaptor
mm
1
Density of
flue gas
flow
g/s
2
Flue gas
tempera-
ture
oC
3
Minimum
draft
Pa
4
Density of
flue gas
flow
g/s
5
Flue gas
temperature
oC
6
Minimum
draft
Pa
7
0,8
Minimum
draft
Pa
4
150
-
-
-
6
320
14
11
With closed doors
With open doors
Data for calculation of the chimney
Column 2 and 5 show the flue gas temperature in the connecting adaptor
Column 3 and 6 show the lowest/minimum draft in Pa by rated value
Column 7 shows the lowest/minimum draft in Pa by 0.8 x rated value