Key Repeat
When set to '
On
', allows you to
press and hold
keys like
▼
or
▲
to navigate through the menu faster. Default is
On
.
Press
◄
or
►
to select
On
or
Off
.
LCD BlinkOff
For alternating text displays, sets the display time for the
secondary
display element. (
object number
,
channel name
,
ID name/number
,
search name, scan list number
)
Enter the amount of time,
1 - 250
(10 - 2500 ms). Enter
1
for 'off'. Default is
150
(
1.5
secs).
LCD BlinkOn
For alternating text displays, sets the display time for the
primary
display element. (
system name
,
scan status
,
scan list name, program
mode, >PAUSED<
)
Enter the amount of time,
1 - 250
(10 - 2500 ms). Enter
1
for 'off'. Default is
50
(
.5
secs).
LED BlinkOff
When the Alert LED setting for an object is set to '
Flash
', this is the amount of time the LED stays turned
off
.
Enter the amount of time,
1 - 250
(10 - 2500 ms). Enter
1
for 'off'. Default is
50
(
.5
secs).
Note:
Alert Mode
must be set to
Both
or
Light
for the LED to function.
LED BlinkOn
When the Alert LED setting for an object is set to '
Flash
', this is the amount of time the LED stays turned
on
.
Enter the amount of time,
1 - 250
(10 - 2500 ms). Enter
1
for 'off'. Default is
5
(
50
msecs).
Note:
Alert Mode
must be set to
Both
or
Light
for the LED to function.
Pri Channels
Sets the number of
conventional
priority channels to check during a priority scan.
0
checks
all
conventional priority channels. Default is
0
.
See also
.
Enter the number of priority channels,
0 - 250
, the scanner will check.
Pri Interval
Sets how often the scanner checks
conventional
priority channels. See also
Enter the amount of time,
2 - 100
(
.
2 - 10 seconds), the scanner will do a priority check. Default is
20
(
2
secs).
TGRP Pri Int
When set to '
On
', the scanner interrupts trunked activity to check for conventional priority channels according to the
Pri Interval
setting when
priority is turned on. Default is
On
.
See also
.
Press
◄
or
►
to select
On
or
Off
.
QuickPriRtn
When set to '
On
', does not wait for verification of correct CTCSS, DCS or NAC when returning to an active conventional channel after priority
sampling. Default is
Off
.
Press
◄
or
►
to select
On
or
Off
.
Search Delay
Sets the delay for all dedicated (Tune, Stalker/Sweeper, Service, Limit) search modes.
Enter the amount of time,
1 - 250
(
.
1 - 25 seconds), for the delay. Default is
20
(
2
secs).
SRCH Dig AGC
When set to '
On
', sets AGC for digital audio in all search modes. Useful to compensate for low or high digital audio levels on the system.
Default is
On
.
Press
◄
or
►
to select
On
or
Off
.
SRCH SuprTrk
Alternative
decoding algorithm is applied to all search types. When set to '
On
', may help reception on some systems. Default is
On
.
Press
◄
or
►
to select
On
or
Off
.
TLO=FUNC L/O
Controls the operation of the
L/OUT
key.
Temporary
lockouts reset when the scanner is turned off.
When set to '
No
', pressing
L/OUT
performs a
Temporary
lockout of the object and pressing
FUNC
then
L/OUT
performs a
Permanent
lockout. (solid
uppercase
L
in display)
When set to '
Yes
', pressing
L/OUT
performs a
Permanent
lockout of the object and pressing
FUNC
then
L/OUT
performs a
Temporary
lockout. (blinking
lowercase
l
in display)
Default is
No
.
Press
◄
or
►
to select
Yes
or
No
.
DupeCheckSQ
If set to '
Yes
', the scanner will check the stored frequency
and
any squelch settings when checking for duplicate conventional objects.
Default is
Yes
.
Press
◄
or
►
to select
Yes
or
No
.
TGID Format
Sets Talk Group ID format display. Default is
Norm
. See also
.
Press
◄
or
►
to select:
Norm
- for EDACS AFS format, Motorola, and LTR systems.
Dec
- for EDACS Decimal format, Motorola, and LTR systems.
Hex
- for EDACs and Motorola - shows IDs in Hexadecimal format.
TGRP Ignore
If set to '
Yes
', TGRP wildcards will not receive IDs (in the same system) that are assigned to disabled Scan Lists. If set to '
No
', TGRP
wildcards will receive IDs mapped to all disabled Scan Lists containing IDs for that system. Default is
Yes
.
Press
◄
or
►
to select
Yes
or
No
.
ShowCCInfo
If set to '
Yes
', shows current control channel frequency alternating with the voice frequency for Motorola and P25 systems. Default is
No
.
Press
◄
or
►
to select
Yes
or
No
.
Set password
Sets power-on password. (default
0000
is no password).
Press
SEL
/
ENT
.
To set new password then press
F1
(
Yes
).
Enter text (or numbers)
for new password and press
F1
(
OK
).
Planning Systems and Scan Lists
Scan Lists
Each
scannable
object (not trunking systems) can be assigned to one
or more
of the 20 main lists, the '
Favorites List
' (#21), or the '
Skywarn List
' (#22).
Each list is scanned like a traditional bank. You can put any type of scannable object in any list with any other type of scannable object. Conventional,