ACSQ PolInt
The interval of time to check for a CTCSS/DCS/
signal.
Default Value 100
(100 ms).
Values:
Enter
10-1000
(10 - 1000 ms).
Menu Help Text:
Interval to poll for
Win500 Name
- Extended Settings>CTCSS/DCS/NAC>
Query Interval
PSREdit Name
- Weather/Advanced Configuration>HD5 Settings>
Query Interval
HD5 Fade
Length of time to wait after losing a CTCSS/DCS/
signal. If the scanner loses programmed CTCSS, DCS, or NAC for the time specified in
that parameter, it will mute audio. Increasing the time may help with the above-described behavior under weak signal or overload conditions. [
]. See
Default Value 2000
(2000 ms).
Values:
Enter
10-2500
(10 - 2500 ms).
Menu Help Text:
fade delay
Win500 Name
- Extended Settings>CTCSS/DCS/NAC>
Fade Timeout
PSREdit Name
- Weather/Advanced Configuration>HD5 Settings>
Fade Delay
HD2 Qualify
Length of time to check to detect an end of signal turn off code command. See also [
Default Value 75
(75 ms).
Values:
Enter
1-1000
(1 - 1000 ms).
Menu Help Text:
end detect threshold
Win500 Name
- Extended Settings>CTCSS/DCS/NAC>
End detect qualify
PSREdit Name
- Weather/Advanced Configuration>HD2 Settings>
Qualify Time (Analog)
Length of time to mute a signal after an end of signal turn off code command.
Default Value 500
(500 ms).
Values:
Enter
10-1000
(10 - 1000 ms).
Menu Help Text:
post-end wait time
Win500 Name
- Extended Settings>CTCSS/DCS/NAC>
Delay after end
PSREdit Name
- Weather/Advanced Configuration>HD2 Settings>
Mute Time
Motorola Trunking
SubaudDelay
Length of time to wait to check for Motorola subaudible data to decode.
Default Value 150
(150 ms).
Values:
Enter
0-65535
(0 - 65535 ms).
Menu Help Text:
Delay before we start subaudible decode
Win500 Name
- Extended Settings>Motorola Trunking>
Subaudible start delay
PSREdit Name
- Weather/Advanced Configuration>Motorola Sub-Audible
Settings>
Delay Time
M36 ET Patt
The Motorola 3600 end tone 16-bit pattern to detect an end of signal command.
Default Value 2B2B
.
Values:
Enter
0x0000-0xFFFF
.
Menu Help Text:
Mot3600 Endtone 16-bit pattern to detect
Win500 Name
- Extended Settings>Motorola Trunking>
Endtone pattern
PSREdit Name
- Weather/Advanced Configuration>Motorola Sub-Audible
Settings>
End Tone Pattern
EndtoneMot
The Motorola 3600 end tone number of bits required to mute at end of signal.
Default Value 80
.
Values:
Enter
0-250
.
Menu Help Text:
# of >baud bits to trig 3600CC analog end
Win500 Name
- Extended Settings>Motorola Trunking>
Endtone threshold
PSREdit Name
- Weather/Advanced Configuration>Motorola Sub-Audible
Settings>
End Tone Threshold
EDACS Trunking
-
these settings control how the scanner behaves after it has already recognized a "call grant" message. [
]
EndtoneEDACS
While on a "voice frequency", qualifying time in bits for the "endtone" to indicate end of transmission. [
]
Default Value 10
.
Values:
Enter
0-250
.
Menu Help Text:
# of >baud bits to trig 4800CC analog end
Win500 Name
- Extended Settings>EDACS Trunking>
Endtone threshold
PSREdit Name
- Weather/Advanced Configuration>EDACS Settings>
End Tone Threshold
EDACS UnMute
After tuning to a 'voice frequency', a delay before unmuting audio. [
]
Default Value 18
(180 ms).
Values:
Enter
0-100
(0 - 1000 ms).
Menu Help Text:
EDACS unmute delay
Win500 Name
- Extended Settings>EDACS Trunking>
GCG unmute delay
PSREdit Name
- Weather/Advanced Configuration>EDACS Settings>
GCG Unmute Delay
EDACS ET HO
After returning to the
from a "voice frequency", how long to ignore any calls on the same "voice frequency". [
]
Default Value 35
(350 ms).
Values:
Enter
0-100
(0 - 1000 ms).
Menu Help Text:
EDACS post end-tone holdoff
Win500 Name
- Extended Settings>EDACS Trunking>
Endtone holdoff
PSREdit Name
- Weather/Advanced Configuration>EDACS Settings>
End Tone Holdoff
Signal Stalker/Spectrum Sweeper Settings
Max Tunes
This setting value appears to set the number of tunes (frequencies) prior to restart of new Stalker/Sweeper group. [
]
Default Value: 20
(frequencies).
Values:
Enter
1 to 1000
tunes
(frequencies).
Menu Help Text:
Max search tunes per scan loop
Win500 Name
- Extended Settings> General Tuning>
Max cached tunes
PSREdit Name
- Weather/Advanced Configuration>Sweeper/Search
Options>
Resume Delay Time
Stalk(Sweep)ScanSQ2
Length of time to wait for a signal on a frequency during Stalker/Sweeper while
scanning
(large signal quality).
Default Value 5
(5 ms).
Values:
Enter
1-100
(1 - 100 ms).
Menu Help Text:
Stalker/Sweeper scan large sig qual
Win500 Name
Extended Settings>Spectrum Sweeper>
Wide SQ timeout
PSREdit Name
- Weather/Advanced Configuration>Sweeper/Search
Options>
Squelch Delay in Scan Mode
Stalk(Sweep)SrchSQ2
Length of time to wait for a signal on a frequency during Stalker/Sweeper while
searching
(large signal quality).
Default Value 5
(5 ms).
Values:
Enter
1-100
(1 - 100 ms).
Menu Help Text:
Stalker/Sweeper search large sig qual
Win500 Name
Extended Settings>Spectrum Sweeper>
Narrow SQ timeout 2
PSREdit Name
- Weather/Advanced Configuration>Sweeper/Search
Options>