3.8
Battery charger and battery charging
3.8.1
General description
The battery charger is using two different modes of charging. Initially the unit will
charge with a high current until the battery is charged, and then it reduces to a
trickle charge mode until battery is removed. The normal charging time for an empty
battery is approximately 3 hours. The battery charger is designed not to damage the
battery even with long continuous charging (see figure 3.12).
Figure 3.12 The battery charger.
3.8.2
Installation
•
The battery charger must be mounted in a vibration free area inside the cab or
indoors and be protected against damp, direct sunlight and temperature
variations.
•
Operating ambient temperature is 0° C to +70° C, but could be narrower
depending on the battery specification.
•
The supply voltage to the battery charger should be +10 VDC to +35 VDC,
externally fused with 3.0 Amp fuse.
•
The batter charger is constructed so that no damage will occur from long
continuous charging.
•
Polarity for connection cable: Inc Marked Cable = +
•
Maximum power consumption for battery charger with battery: ≈ 400 mA
•
Power consumption for battery charger without battery: ≈ 10-20 mA
•
After connection the cable connector, put the cable inside the cable track as
illustrated in figure 3.13 below.