Document type
Document number
Rev
Page
Manual
66024
C
32 of 37
6.2.1
Operational status indications
The Portable Control Unit uses LED ON and LED MICRO to indicate current status and
alarms.
A functional system should indicate the following on LED ON:
LED ON lit red; this means that the Portable Control Unit is active and transmitting
data towards the Central Unit either via cable or radio.
LED ON flashing red once every second; this means that the battery is
approaching time for charging, this indication precedes by the buzzer that beeps
three (3) times.
LED MICRO is used to indicate current micro mode
LED MICRO flashing green one, two, three, four or five times every third
second; this means that the micro function is active, see chapter 3.3.6 for further
information.
6.2.2
Error codes
During start-up of the Portable Central Unit a self test is conducted, any errors found
are presented by an error code using ON LED and buzzer flashing/alarming a certain
amount of times, the number of times represents a certain error:
Indications
Meaning
1
Lever/Joystick at position 1 not in neutral position at start-up or
defective
2
Lever/Joystick at position 2 not in neutral position at start-up or
defective
3
Lever/Joystick at position 3 not in neutral position at start-up or
defective
4
Lever/Joystick at position 4 not in neutral position at start-up or
defective
5
Lever/Joystick at position 5 not in neutral position at start-up or
defective
6
Lever/Joystick at position 6 not in neutral position at start-up or
defective
7
Lever/Joystick at position 7 not in neutral position at start-up or
defective
8
Lever/Joystick at position 8 not in neutral position at start-up or
defective
13
Emergency stop failure during self test
32/37