COMPACT 75
COMPACT 75
Operator’s manual for drilling machine
- 10 -
6. INSTALLING AND UNINSTALLING THE ARBOR
The arbor installation and uninstallation should be carried out when the
machine is turned off and disconnected from the power grid!
Installing the arbor:
1.
Raise the guard (2) to the maximum.
2. Clean the inside of the spindle using a cotton cloth.
3. Before mounting, clean off the lubricant from the new arbor
(3).
4. Place the arbor with the fin on top, and place it in the spindle.
5. By turning the arbor, align the fin to the appropriate slot in the spindle.
6. Using a light impact from the bottom side, drive the arbor into the spindle.
Uninstalling the arbor:
1. Raise the guard;
turn the spindle so that the wedge MT opening in the spindle (1) is lined up
with the wedge MT opening in the reducer body.
2.
Place the wedge MT (included as standard equipment) into the uncovered spindle opening
(1).
3.
Hold down the arbor (3) wit
h one hand.
4. Strike the wedge MT with a hammer, taking care to not to damage the arbor.
5. Carefully remove the arbor from the socket in the spindle.
6. Remove the wedge MT.