Chapter 4: Maintenance
Maintenance Schedule
74
Scantron
i
NSIGHT 30 Scanner
Clean imaging guides
Daily
Use staticide wipe, (part
number 830 9783) -- slightly
damp. Wipe with a dry
staticide wipe before
scanning. If dust is on the
underside of the imaging
guide, remove the imaging
guide and clean. WIPE
AWAY FROM THE
PATCH to avoid leaving
dust or debris on the patch.
Clean paper path
Daily
Use emulsiclean wipe, (part
number 137 4966) in
transport area and on red
and white rollers. Allow to
air dry.
CAUTION:
DO NOT USE
THE EMULSICLEAN
WIPE ON THE
FOAM TIRES.
Replace separator
module and separator
module tires
Every 200,000
documents scanned
Use parts from feeder
consumables kit, (part
number 880 9485).
Replace pre-separation
pad
Every 250,000
documents scanned
Use parts from feeder
consumables kit, (part
number 880 9485).
Replace feed module
and feed module tires
Every 500,000
documents scanned
Use parts from feeder
consumables kit, (part
number 880 9485).
Replace imaging guides
Only when guides are
scratched or damaged
Use upper imaging guide
(part number 169 5790) or
lower imaging guide (part
number 857 5292).
Procedure
Interval
What to Use
Summary of Contents for iNSIGHT 30
Page 1: ...Operator s Guide iNSIGHT tm 30 ...
Page 2: ...Operator s Guide iNSIGHT tm 30 ...
Page 12: ...Operator s Guide xi Pencil Form Color Combinations 3 Color 152 ...
Page 13: ...xii Scantron iNSIGHT 30 Scanner ...
Page 28: ...Chapter 1 iNSIGHT 30 Dual Purpose Scanner Power System Connection Operator sGuide 15 NOTES ...
Page 113: ...Chapter 4 Maintenance Replacing the Imaging Guides 100 Scantron iNSIGHT 30 Scanner NOTES ...
Page 157: ...Chapter 7 Product Support and Services Services 144 Scantron iNSIGHT 30 Scanner NOTES ...