background image

00:01 MON 01 JAN

ENTER CODE

****

SET SYSTEM?

Press No

SET UP OPTIONS

Press Yes

SET CHIME?

SET TIME ?

Press No

ENTER HOURS

ENTER MONTH

Key-in month e.g., 1=Jan

ENTER DATE

Key-in date e.g., 1

Press Yes

Key-in day e.g., 3= Wed

ENTER YEAR

Enter the last two digits of

the year e.g., 91

System will display

programmed time and date

Enter time in

Hours e.g., 14

(24hr Clock)

ENTER MINUTES

Enter time in

Minutes e.g., 01

SET DATE ?

MANAGER AUTHORITY ONLY

Key-In valid

Access Code

Press Yes

Press Yes

Press Yes

Press Yes

Press Yes

Press Yes

Press Yes

C

HANGING

 T

IME

 A

ND

 D

ATE

13

12

ENTER DAY

MON=1 SUN=7

14:01 WED 01 JAN

Summary of Contents for 9600

Page 1: ...Microprocessor Intruder Alarm Control Panel User Manual 9 6 0 0 ...

Page 2: ...AFTER ALARM CONDITION 8 8 DAYTIME TAMPER ALARM 9 9 SILENT PERSONAL ATTACK ALARM 10 10 FIRE ALARM 11 11 CHIME FUNCTION 12 12 CHANGING TIME AND DATE 13 13 CHANGING MANAGER 1 CODE 14 14 CHANGING USER CODE AUTHORITY 15 15 OMIT 24 HOUR ZONES 16 16 BELL TEST 17 17 SYSTEM WALK TEST 18 18 VIEW EVENT LOG 19 19 DISPLAY MESSAGES 20 20 YOUR CIRCUIT DESCRIPTION 22 21 SERVICE RECORD 23 22 SERVICE CONTACT 24 CON...

Page 3: ...tem time and date f Changing user code authority g Changing and deleting user codes h Viewing the event log i Carrying out all test functions e g Bell Test and Walk Test j Printing the event log Operator Codes Restricts user access to the following system functions a Arming disarming and resetting the system if not programmed for Engineer Reset b Omitting zones if zones are programmed to be Omit A...

Page 4: ...alling The Duress code is used to transmit a Personal Attack P A alarm to the central station in the event of the user being required to unset the system under duress Using the Duress code will unset the system but will give no visual evidence of the transmission to the central station IMPORTANT NOTE Do not use the Duress code to unset the system unless under duress as the transmission of a PA cod...

Page 5: ...ters a valid code and there are no faults present If faults exist the keypad will emit a single error beep and cycle through any faults for the duration of the pro grammed exit time and then return to the day state Check for faults as necessary Key in valid Access Code 00 01 MON 01 JAN ENTER CODE SET SYSTEM SELECT AREA Key in group to be set See Note 1 OMIT ZONES LEAVE AREA Press Yes Press No Soun...

Page 6: ... time Press Yes Press No 4 ARMING WITH OPEN FAULTY ZONES 3 Note 2 When selecting groups to be armed select Group A for Full Guard or select group B C or D for Part Set Guard Note 3 If a detector is fitted at the control panel or if the front door is known to be open you may leave if these faults are shown The system will set when clear of the detection If the user is not clear by the time the exit...

Page 7: ...T ZONES Press No LEAVE AREA ZONES OMITTED Press Yes 5 SETTING WITH CIRCUITS OMITTED Note 2 Only circuits programmed by the engineer as Omit Allowed can be omitted Display will show CANNOT OMIT if not programmed 4 Leave the premises via the prescribed exit route The alarm system will automatically set on expiry of the exit timer or closing of final door or pressing the exit terminate button Refer a...

Page 8: ...escribed entry route during the First Ply entry time the system will automatically change from the Entry mode to the Abort mode if programmed by the installer The entry timer will change to a second ply fixed timer of 90 seconds along with a rapid warning tone The user must enter a valid user code during the 90 seconds otherwise an alarm will be initiated If the user exceeds the entry timer and de...

Page 9: ... Page 3 ARMING DISARMING BLOCK OMIT GROUP D 7 6 Disarming Group D Block Omit Note 1 if display shows INVALID CODE YES NO press the Yes or No key and re enter your access code Note 2 The 9610 control panel has a special user access code known as Block Omit By entering this code it allows all the circuits allocated to Group D to be armed or disarmed while any of the three other groups is armed The c...

Page 10: ...id access code or CALL ENGINEER PIR HALL System has been programmed for Engineer Reset Call alarm company to reset system Note 2 A normal alarm zone has caused the alarm condition DISARMING AFTER ALARM CONDITION 8 7 Note 3 An anti tamper circuit which protects the system caused the alarm condition Call the engineer to investigate cause before resetting Note 4 A fault has occurred within the contro...

Page 11: ...d e g PIR HALL TAMPER PIR HALL RESET REQUIRED Call alarm company engineer to repair system Alternates between DAYTIME TAMPER ALARM Note 1 The 9600 system incorporates 24 hour monitoring on all wiring and detection devices If this circuit is violated it will cause a Tamper condition warning the user of any unauthorised interference by operating the internal sounders 9 8 ...

Page 12: ...ENTER CODE SYSTEM NOW RESET Note 1 If the Silent Personal Attack function has been programmed operating a P A button will cause the remote signalling to transmit a signal to the alarm company central station There will be no audible evidence of P A activation Press Yes Key in a valid Access Code 00 01 MON 01 JAN Silent transmission to the alarm company central station 10 SILENT PERSONAL ATTACK ALA...

Page 13: ...he system has remote signalling fitted a fire code will be transmitted to the alarm company central station The necessary information may be passed to the nearest fire station In any event always dial 999 and call the fire brigade To reset system Key in a valid Access Code ENTER CODE 00 01 MON 01 JAN If safe to do so enter valid code to silence alarm Evacuate all occupants of the building and call...

Page 14: ...ion engineer as Chime zones will operate this facility Press Yes Press Yes Chime function ON CHIME FUNCTION 12 11 Note 2 Opening a zone which has been programmed as Chime will cause a bleep tone to be emitted from the internal speaker s Press No Chime function OFF Press Yes Press No button 5 times to return panel to time and date SET TIME 00 01 MON 01 JAN ...

Page 15: ...in day e g 3 Wed ENTER YEAR Enter the last two digits of the year e g 91 System will display programmed time and date Enter time in Hours e g 14 24hr Clock ENTER MINUTES Enter time in Minutes e g 01 SET DATE MANAGER AUTHORITY ONLY Key In valid Access Code Press Yes Press Yes Press Yes Press Yes Press Yes Press Yes Press Yes CHANGING TIME AND DATE 13 12 ENTER DAY MON 1 SUN 7 14 01 WED 01 JAN ...

Page 16: ...E CODES Press Yes to retain access code 1234 MANAGER ENTER CODE Press No button 3 times See Note 1 Change user codes page 15 Press No Press Yes Press No button 3 times Press Yes Press No to change access code Press Yes 14 CHANGING MANAGER 1 CODE 13 MANAGER AUTHORITY ONLY Note 1 User 1 Access Code is al ways the manager It can not have the authority changed Note 2 The system will not accept a Zero ...

Page 17: ...RITY MANAGER Press No SELECT AUTHORITY OPERATOR Press No SELECT AUTHORITY BLOCK OMIT Press No SELECT AUTHORITY DELETE Press No SELECT AUTHORITY DURESS Press No SELECT AUTHORITY HOLIDAY Press No SELECT AUTHORITY ENTRY CHANGE CODES Note 1 If No is pressed when the dis play shows ENTER NEW CODE the existing code will be retained ENTER NEW CODE 00 01 MON 01 JAN Press No CHANGING USER CODE AUTHORITY 15...

Page 18: ...osed before removing omit Press Yes 24 hour zones are automatically re instated 00 01 MON 01 JAN OMIT 24 HOUR ZONES Press Yes to repeat procedure REMOVE OMIT SET UP OPTIONS SET CHIME 00 01 MON 01 JAN OMIT 24 HOUR ZONES SET UP OPTIONS SET CHIME Key in a manager Access Code Note 1 Zones which have been left as 24 hour omit will automatically be re instated when the system is armed in Part or Full se...

Page 19: ...lautomaticallytesteach warning device for 3 seconds Key in a Manager Access Code Press No button twice TESTING STROBE TESTING KEYPAD TESTING BELL TESTING SOUNDER BELL TEST Press Yes BELL TEST 17 Note 2 Pressing the No key during the test will abort the test 16 ...

Page 20: ...JAN Press No button 3 times Display will show any circuits which are open or Key in Manager Access Code SET SYSTEM WALK TEST WALK TEST NO VIOLATIONS WALK TEST FRONT DOOR 00 01 MON 01 JAN Press No to end Walk Test Note 2 When a zone is opened the keypad bleeps and the in ternal sounder s operate The display will show de scription of circuits Press Yes SYSTEM WALK TEST 18 17 ...

Page 21: ... number 3 key PRINT LOG Press Yes Press No 00 01 MON 01 JAN Press No button 4 times SET SYSTEM Key in a valid Access Code 00 01 MON 01 JAN Press Yes The log is printed to a printer if connected Press No Note 1 The control panel has an internal log which is capable of logging 250 events Press No to stop printing Only if a Manager code is used and Loggin Printer is not selected by the installer Note...

Page 22: ...een violated Call engineer to check system CALL ENGINEER Call alarm company engineer to check system INVALID CODE Incorrectusercodehasbeenentered re tryupto4timesbefore tamper alarm will occur LOW BATTERY Stand by battery is low call alarm company engineer to check system MAINS FAILED 240vmainsupplytocontrolpanellost checkfuseboardorspur outlet Call engineer to check if required SYSTEM FAULT Fault...

Page 23: ...must be restored to the system in the near future otherwise the system will fail completely SYSTEM INHIBITED If there are two or more keypads fitted to the system all keypads except the one in use will display SYSTEM INHIB ITED during engineering TELEPHONE FAILED The telephone line has become disconnected or faulty If possible check the connection to the panel If the message persists contact the i...

Page 24: ...TION COMMUNICATOR FITTED EXIT TIME ENTRY TIME D GROUP 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 ZONE DESCRIPTION A OMIT ALLOWED CHIME YOUR CIRCUIT DESCRIPTION 22 C B D 20 GROUP C B A Note Group D can be either Part Set or Block Omit depending on the way the system is programmed ...

Page 25: ...ENG DATE REPORT SERVICE RECORD 23 21 ...

Page 26: ...COMPANY NAME ADDRESS CONTRACT Nº YOUR SERVICE CONTACT 24 22 Service Telephone Number ...

Page 27: ...ic Ltd Perivale Industrial Park Greenford Middx UB6 7RJ England Tel 081 991 1133 Telex 915 810 SCANCO G Fax 081 997 4448 Customer Support UK Tel 0800 373767 or 0594 543343 Pt No 496655 MAY 91 Issue 1 SCANTRONIC ...

Reviews: