Part No. SCAZ037886 8.6.00
31
E&OE
Merlin and Magnum Hydrostatic
Operating Instructions
Key maintenance procedures
Cleaning the suction fan and screen
Failure to comply with the following could result in serious injury.
Before working on the machine position it on firm, level ground and apply handbrake.
The fan is an extremely heavy rotating mass. never attempt to slow or stop its rotation by using the hands or by inserting any item into the fan
chamber, even at low speeds.
1. Turn engine OFF. Remove Ignition key. Use a suitable platform
to enabling you to reach the area above the rear door.
2. With the fan stationary, remove the outer and inner
inspection covers from the hopper to expose the fan.
3. Using the special scraper, thoroughly clean all parts of the fan.
A steam-cleaner or high-pressure water from a remote source
will greatly assist in cleaning severely contaminated fans.
4. Refit the inspection covers and open the rear door
. Lower
the screen. Wash the screen using steam or high-pressure
water.
Raise the screen and close the rear door.
Never work under a raised rear door unless the prop is in the deployed position.
Loose particles from the cleaning process can be ejected via the hopper cover when the fan is restarted, ensure that all personnel are clear before
restarting.
5. Start engine. Select sweep mode
. Fan ON
.
6. With the rear door shut, direct additional water on to the screen below the fan inlet cone, from an open side-access flap, until only clean water is
expelled from the fan casing.
Please pay particular
attention to inner
curve of blade and
also the centre of the
unit where dirt
accumulates around
the hub area.