IM020
SC-SI30K51
5
If you have too hard water,it is advisable to use only distilled or demineralized water.
When re-filling the tank with water, always disconnect the iron from the mains
In the end, it is always necessary to completely remove the water from the reservoir and/ or set the variable steam
control mode to
avoid water leakage from holes.
NOTE: After draining water from the cooled iron, set it upright (on the heel) and turn on for 2 minutes at maximum heat,
then remove the iron from the mains.
SPRAYING
As long as there is enough water in the water tank, you may use the spray button at any temperature setting during
steam or dry ironing.
Press the spray button several times to activate the pump while you are ironing.
STEAM IRONING
With the unit unplugged, fill the steam iron with water.
Stand the steam iron on its heel rest in an upright position on an iron-safe surface and plug in.
Set the temperature control dial to the “••“ or “•••” position.
When the indicator light is off, the steam iron has reached desired temperature.
Set the variable steam control to the desired position.
When finished, turn the temperature dial counterclockwise to the minimum position and unplug the appliance from the
power supply.
CAUTION: Avoid coming in contact with ejected steam.
DRY IRONING
The steam iron can be used on the dry setting with or without water in the water tank, however it is best to avoid having
the water tank full while dry ironing.
Turn the variable steam control to the minimum position.
CAUTION: If the steam iron has been used for a long time, it is hot and there is no water. Do not refill it with water until
the steam iron cools down.
BURST OF STEAM
The burst of steam feature provides additional steam for removing stubborn wrinkles.
Set the variable steam control to maximum steam
, set the maximum temperature on the controller, wait a moment
and click the steam blow.
NOTE: To prevent water leakage from the soleplate, do not keep the powerful steam button pressed for more than 5
seconds.
NOTE: For the best steam quality, do not use more than three successive bursts each time, because the iron will cool.
VERTICAL STEAM
Ensure that there is enough water in the water tank.
Stand the steam iron on its heel rest on an iron-safe surface and plug it.
Set the temperature control dial and variable steam control to their maximum positions.
Hold the iron vertically and press the steam burst button, an intense steam will be ejected from the soleplate.
WHEN YOU FINISHED IRONING
Set the temperature dial to the minimum position.
Remove the mains plug from the wall socket.
AUTOMATIC TURN-OFF
This function turns the iron off automatically if the iron remains in horizontal position for more than 30 seconds or if the
iron stands vertically for more than 8 minutes. This function completely eliminates the risk of fire.
CARE AND CLEANING
Before cleaning the steam iron ensure it is unplugged from the power supply and has completely cooled down.
Do not use abrasive cleaners.
SELF-CLEANING
Fill water reservoir up to the maximum level and then close it.
Set the temperature control to its maximum position.
Insert the main plug into the wall socket.
Allow the iron to heat up until the indicator light goes out.
Holding the iron horizontally over the sink then set the variable steam control to "SELF CLEAN".
Boiling water and steam will be ejected from the holes in soleplate with Impurities washed out. Rock the iron forwards
and backwards during this operation.
Repeat self-cleaning if you notice that much impurity has been washed out.
Move the iron over an old (preferably) piece of cloth. This to ensure that the soleplate will be dry during storage.
STORAGE
Unplug the appliance from the power supply, empty the water tank (do it after each use) and allow the steam iron to
cool down completely.
Wrap the cord around the heel rest.
To protect the soleplate, place the steam iron in an upright position on its heel rest.
The symbol on the unit, packing materials and/or documentations means used electrical and electronic units and
battery’s should not be toss in the garbage with ordinary household garbage. These units should be pass to special
receiving point.
For additional information about actual system of the garbage collection address to the local authority.