background image

B

9

SAGINAW CONTROL & ENGINEERING  •  A/C USER MANUAL

back to top

11. Electrical Connection

12. Controller Programming

The cooling unit is used where heat needs to be dissipated from electrical control cabinets or similar enclosures in order to 

protect heat sensitive components. The unit has two completely separate air circuits which ensure that the clean cabinet 

air does not come into contact with the ambient air which may well be dirty or polluted. Control cabinet air conditioners can 

dissipate large quantities of heat from sealed enclosures, such as control cabinets, into the ambient air and at the same time 

reduce the cabinet internal temperature to below that of the ambient air.

The control cabinet air conditioner can function without problems in extreme ambient conditions (e.g. dusty and oily air) 

with a standard operating temperature ranging between -4°F and 131°F. The stated cooling capacities are according to DIN 

3168.

Door Switch

The unit can be switched on and off via a door contact switch. When delivered the door contact terminals are bridged on the 

female connector. To connect the door contact switch remove the bridge and connect door contact switch. The contact must 

be closed when the cabinet door is closed.

SET

TEST

BMS

PRG

R
D

!

1

2

3

4

The cooling unit is intended to be used as a complementary accessory to larger industrial

equipment. The unit is used where heat needs to be dissipated from electrical control 

cabinets or similar enclosures in order to protect heat sensitive components. It is not 

intended for household use. The unit has two completely separate air circuits which 

ensure that the clean cabinet air does not come into contact with the ambient air which 

may well be dirty or polluted. Enclosure cooling units can dissipate large quantities of 

heat from sealed enclosures such as electrical enclosures into the ambient air and at 

the same time reduce the cabinet internal temperature to below that of the ambient air.

The  unit  can  function  without  problems  in  extreme  ambient  conditions  (e.g.  dusty 

and  oily  air)  with  a  standard  operating  temperature  ranging  between  +10°C  and 

+55°C.  Units  can  be  ordered  with  an  additional  electrical  cabinet  heater.  For  the 

cooling capacities and environmental ratings please refer to the type plate data.

The display shows the temperature in the range of -50°C to +150°C (-58°F to +302°F). The

temperature is displayed with resolution of tenths between -19.9°C and +99.9°C (-3.8°F 

to +211.8°F). During programming, it shows the codes and values of the parameters. The 

display also shows icons according to occurring events.

Controller

Summary of Contents for Enviro-Therm SCE-AC8500B460V

Page 1: ...unting p 7 8 Mounting Principle p 7 9 Cutout Dimensions p 8 10 Dimensions H x W x D p 8 11 Electrical Connection p 9 12 Controller Programming p 9 13 Wiring Diagram p 13 14 Taking Into Operation p 15 15 Repair p 15 16 Maintenance Cleaning p 16 17 Transport Storage p 16 18 Parts Supplied p 16 19 Warranty Limits of Liability p 17 User Manual SCE AC8500B460V SCE AC8500B460VSS SCE AC8500B460VSS6 ...

Page 2: ...oltage Indicates electric shock danger Important Safety Instruction Indicates instructions for safe maintenance and operation of the unit Attention Indicates possible burns from hot components Attention Indicates possible damage to the unit Instruction Indicates possible danger to the environment Liability The information data and instructions contained in this instruction manual are current at th...

Page 3: ...ty regulations One can find dangerous voltage above 50V AC or above 100V DC Behind the control cabinet doors On the power supply in the unit housing The units have to be fused according to the type plate and the wiring diagram Switch the unit off immediately if the electric power supply is interrupted Danger Through Incorrect Work on the Unit Only specialized personnel are allowed to maintain and ...

Page 4: ...oke and evaporator These four components of the refrigerant plant are connected with each other by pipes to form a hermetically sealed system in which the refrigerant R134a circulates 1 Air Intake Cabinet Side 2 Radial Fan Cabinet Side 3 Evaporator 4 Air Outlet Cabinet Side 5 Compressor 6 Air Intake Ambient Side 7 Radial Fan Ambient Side 8 Condenser 9 Air Outlet Ambient Side 10 Filter Dryer 11 Exp...

Page 5: ...S6 Stainless Steel AISI 316 Dimensions H x W x D 61 02 x 18 00 x 13 98 inch Weight 172 lbs Cutout Dimensions 14 80 x 12 80 inch 14 80 x 13 20 inch Rated Operating Voltage Frequency 400 460 V 50 60 Hz Rated Current 95 F 95 F 2 6 A Starting Current 6 8 A Max Current 3 6 A Power Consumption 95 F 95 F 940 W Max Power Consumption 1 64 kW Fuse Rating 9A T Time Delayed Slow Acting SCCR 5kA Transformer In...

Page 6: ...city BTU SCE AC8500B230V SCE AC8500B120V SCE AC8500B460V SCE AC8500B230VSS SCE AC8500B120VSS SCE AC8500B460VSS SCE AC8500B230VSS6 SCE AC8500B120VSS6 SCE AC8500B460VSS6 Enclosure Air Temp 131 F 55 C 122 F 50 C 95 F 35 C 68 F 20 C Cooling Capacity Watt Ambient Temperature F 65 75 85 95 105 115 125 135 18 24 29 35 41 46 52 57 14000 12000 10000 8000 6000 4000 4102 3516 2930 2344 1758 1172 ...

Page 7: ...ntering the cooling unit internal and external are not obstructed Cooling unit enclosure air suction hole must be installed at the highest possible point When installing the unit on a door ensure it can take the weight Before drilling the enclosure ensure the fixing elements and couplings will not interfere with the equipment inside the enclosure itself Disconnect power before starting any work in...

Page 8: ...top 9 Cutout Dimensions 17 99 14 02 61 02 61 02 17 99 1 97 12 80 12 01 13 19 21 06 14 84 8 07 8 07 93 98 98 1 58 16 14 13 19 11 22 14 57 14 17 6 89 312 x11 MOUNTING PATTERN INTERNAL AIR OUTLET INTERNAL AIR INLET ELECTRICAL CONNECTIONS 10 Dimensions H x W x D ...

Page 9: ...ed when the cabinet door is closed SET TEST BMS PRG R D 1 2 3 4 The cooling unit is intended to be used as a complementary accessory to larger industrial equipment The unit is used where heat needs to be dissipated from electrical control cabinets or similar enclosures in order to protect heat sensitive components It is not intended for household use The unit has two completely separate air circui...

Page 10: ...ess Flashes when activation is delayed or inhibited by protection times external disabling or other procedures in progress Flashes when alarms are active Signals operation of unit in heating mode Activated only by manual procedure Setting cooling set point St1 Setting heating set point St2 only for units supplied with internal heater 1 Press SET and display should show St1 and then the pre set val...

Page 11: ... high temperature alarm threshold default 55 C 131 F 3 Press SET on the desired parameter to display the current value 4 Use or to reach the desired value 5 Pressing SET temporarily saves the new value and returns to the parameters list 6 Repeat steps 2 5 to set other parameters 7 Press PRG for 5 seconds to permanently save the new values Test Function Different test functions can be used dependin...

Page 12: ... no button is pressed for 10 seconds the display starts flashing and after 1 minute returns to the main display without saving changes l To increase scrolling speed press and hold the or button for at least 5 seconds When pressing PRG for 3 seconds the firmware revision code is displayed for 2 seconds When cleaning the controller panel do not use ethanol hydrocarbons ammonia or their byproducts Us...

Page 13: ...former Connector X4 Electrical Supply Connections 400 V 460 V 1 1 L1 460 V 2 LX 400 V 2 3 L2 400 460 V 3 L2 400 460 V 4 Earth Ground 4 Earth Ground 5 P1 High Temp alarm NO 5 P1 High Temp alarm NO 6 P2 High Temp alarm COM 6 P2 High Temp alarm COM 7 P3 High Temp alarm NC 7 P3 High Temp alarm NC 8 T1 Door Switch Contact 8 T1 Door Switch Contact 9 T2 Door Switch Contact 9 T2 Door Switch Contact Notes ...

Page 14: ...B 14 SAGINAW CONTROL ENGINEERING A C USER MANUAL back to top ...

Page 15: ...ting temperature St Verify values of parameter St Door switch contact is open Verify door switch Controller does not work Replace controller Internal fan works external fan and compressor do not work Display shows alternating OFF and temperature The sequence of the phases inside the power supply connector is incorrect Change phases inside power supply connector External and internal fan work compr...

Page 16: ...ashers 1 x Female Connector with shorted wired positions for door contact Saginaw Control and Engineering 95 Midland Road Saginaw MI 48638 5770 Phone 989 799 6871 Fax 989 799 4524 sce saginawcontrol com Always switch power supply off before starting any maintenance on the unit Any repairs that may be needed must only be done by qualified personnel The cooling unit is a low maintenance type and for...

Page 17: ...not exceed minimum and maximum rated temperatures Must not exceed BTU Hr rating Filters must be cleaned regularly Must be installed and grounded in accordance with all relevant electrical and safety codes as well as the National Electric Code and OSHA rules and regulations Must be installed in a stationery application free of vibration Our warranty does not warranty product that has been modified ...

Reviews: