E-649RA
- User Manual
• 7
EN
FR
IT
OPERATIONS AND WARRANTY CONDITIONS
Operation data: For reliable and safe function of the tool it is necessary to adhere to instructions
and principles stated above. Immediately before the tool there must be a regulation valve set to
maximum outlet pressure of 0.7 MPa, air filter and lubrication in the circuit of compressed air.
Final level of exposure to noise standardized for regular working day of 8 hours is L
Aeq,T
= 95.7
dB(A), peak C-weighted sound pressure, C
LCpeak
= 104.4 dB(C), against which during continuous
and long-term operation it is recommended to use ear protectors. Average total weighted level of
vibration acceleration is L
ahv,T
= 118.3 dB re 10
-6
ms
2
. Average total weighted effective value of
vibration acceleration is a
hv,T
= 0.822 m.s
2
.
The trigger enables safe control of the tool with a force max. 10 N < 50 N without releasing the
grip-handle according to the health regulation.
For the warranty period the customer must not perform any alterations other than
those permitted by the manufacturer. Other nondetachable
parts are secured with paint. In case of neglecting this protection the
manufacturer shall not admit possible warranty repairs. To admit warranty repair
the customer must submit confirmed warranty certificate of the tool, Certificate of
quality and completeness or proof of purchase. The warranty period is 12 months
from the day of purchase confirmed in the Warranty certificate if the purchase
contract does not state otherwise.
1. OPERATION CONDITIONS
2. WARRANTY CONDITION
QUALITY CERTIFICATE OF E-649RA TOOL
The provisions of the Product Technical Specifications Act 22/97 Coll. including the respective
Decree of the Goverment specifying individual products criteria apply to the hydraulic/ air-
operated riveting tongs. Under this Act, the product was tested by the accredited testing
laboratory for the hand-operated tools of State Testing Laboratory No. 214 WUÛ Ostrava-
Radvanice. When testing the product pursuant to Governmental Instruction No.24/2003 Coll.
Coincident with direction EU 98/37/EC, CSN EN 792 - 1 and the connected paragraphs of Decree
No.48/82 Coll. issued by the CÛBP, the laboratory has found out that the product meets the
abovementioned regirements.
The producer declares the meeting of the legal obligations including the determined quality of the
product by the written DECLARATION OF CONFORMITY attached to each dispatched shipment.
Warranty is valid provided that the following:
- «GENERAL SAFETY INSTRUCTIONS AND PRINCIPLES» p.2
- «2. TOOL OPERATION» p.3
- «1. DAILY MAINTENANCE» p.5
- «2. WEEKLY MAINTENANCE» p.5
- «STORAGE» p.6
- «OPERATIONS AND WARRANTY CONDITIONS» p.7
The warranty does not apply to quickly expendable parts (see paragraph «2. LIST OF QUICKLY
EXPENDABLE PARTS» p.6).
For reliable function of the tool
we recommend to use treated
compressed air.
Treated compressed air means
compressed atmospheric air
bare of solid particles and water,
reduced to required pressure and
lubricated with anti-corrosive oil.