background image

ISD8001: Industrial ScentDirect  
Diffusion System

 

Wall Mount Instructions

 

 

 
 
OPERATING INSTRUCTIONS 

 
Bottle  -  Installation and  Replacement 
1.

 

Open machine door by turning lock. 

2.

 

Disconnect quick connect “output” tube by pressing the lever and pulling 

up on the tube.  Leave tube in machine. 
3.

 

Disconnect the input (black) tube by depressing the 

“push to release”

 ring 

and simultaneously pulling up on the tubing.  Leave tube in the machine. 
4.

 

R

emove bottle and collector from machine 

5.

 

Open new bottle of fragrance oil 

 save the cap for the empty bottle. 

6.

 

Unscrew the collector from the empty bottle. 

7.

 

Inspect the gasket for imperfections,  damaged gaskets should be replaced. 

8.

 

Install the collector on the new fragrance bottle 

9.

 

Install bottle and collector into the machine 

10.

 

Install input and output tubing 

11.

 

Operate the ISD system using the control features on the inside control panel. 

 
 

INDUSTRIAL SCENTDIRECT ISD-8001 OPERATING INSTRUCTIONS 

1)  Verify that the machine is properly connected to an electrical supply ( see troubleshooting ) 

 

 

2)  SET THE  MASTER POWER TO TIMER 

The display should turn on when the master power switch is moved to the timer 
position. 

3) SET THE TIME 

From this display it is possible to set the clock on your ScentDirect. To do this first press 

the set button once so that “am” and “pm” blink. Next use the plus and minus 

buttons 

to change the time until the accurate time is displayed. Press select again to accept the 
change. The TIMER setting will utilize the integrated timer and provide power to the 
system for a specified amount of time each day. NOTE: IF YOU DO NOT SET UP THE TIME 
IN STEP THREE, YOUR SCENTDIRECT WILL NOT OPERATE CORRECTLY. 

4)  SET THE  TIMER 

Program the timer so your ScentDirect is only active for up to 16 hours per day. 
This will prevent the system from operating during non-business hours and will help 
preserve the life of your fragrance oil. 

    A. Set the Time of Day  
  

Set the time of day by pressing the pr

ogram set button until “AM/PM” begins to flash. 

Use the + or 

 buttons to adjust the time of day 

    B. Set the ON time 

Summary of Contents for ISD8001

Page 1: ...2 and 3 PHILLIPS HEAD SCREW DRIVER 4 SMALL LEVEL 5 Electric drill 6 Drill bits 3 16 5mm and 13mm 7 Masonry Drill bit 5 16 8mm 8 Electronic Studfinder The articulated Wall Mount includes its own hardw...

Page 2: ...to be scented Be sure to mount the ISD out of the reach of children The system can be mounted anywhere from ground level to 12 feet high A good rule of thumb is to mount it above or below nose level a...

Page 3: ...lifted into place onto the mounting plate of the wall mount with the screws in the upper slots of the mount plate shown here Now insert the 4 M6 1x12mm screws included with the mount in the other fou...

Page 4: ...STRUCTIONS 1 Verify that the machine is properly connected to an electrical supply see troubleshooting 2 SET THE MASTER POWER TO TIMER The display should turn on when the master power switch is moved...

Page 5: ...15 60 or 180 seconds the fragrance dispersion will be off during each cycle Start with both switches in the 60 seconds position and adjust the switches as needed after one hour if more or less fragran...

Page 6: ...ngs and the on and off switch to one way and then the other to ensure correct positioning Verify that there is no obstruction in the pick up tube filter Remove any debris on the pick up filter Pump do...

Page 7: ...ernal faceplate as strong solvents may remove the silk screen from the label Collector Cleaning In order to clean the collector for unit storage and or fragrance change Remove collector from unit per...

Reviews: