NSG 438
38
Repetitive discharges are only of real use to quickly localize weak spots in
construction or to pin-point critical situations in program routines. Single
pulses are then to be used for detailed investigations and to assess the
sensitivity to interference.
An exact record is to be kept describing the test conditions complete with
photos of the test rig, details of the type and quantity of discharges, notes
about the ambient climatic conditions, remarks concerning the effects
observed etc.
Example of test set-up for table-top equipment - laboratory tests
Example of test set-up for floor-standing equipment - laboratory tests
Mains connection
Horizontal coupling
plate
Ground reference plane
Bleeder resistor
Insulation
Earth wire
Base
station
PE
Mains connection
with protective earth
Earth wire
Cabinet earthed via
protective earth line
Base
station
Ground reference plane
Insulation pallet
PE