background image

Installation, Mounting and Maintenance DISA-W

Z11/27 - 3

Construction subject to change.

No return possible!

20.10.2015

Version:

Safety instructions

Prior to installation and commissioning of this device, please

read completely through this manual. Please observe in partic-

ular the regulations and operating instructions  containing the

hazard symbols and safety signs. Non-observance can result

both in damage to the device and personal injuries.

If, after reading through the manual, you have further questions,

please contact the manufacturer or the local sales office.

General information

SCHAKO shall not give any warranty for damage resulting from:

Warranty

The device warranty will be for two years starting from the

handover date and shall apply to all production faults. Electric

components are excluded from the device warranty. However,

they are covered by the corresponding warranty of the relevant

manufacturer 

Also excluded from the warranty is damage to the device unit

caused by components that are not part of the device itself.

The warranty only covers the return and replacement of defec-

tive materials.

Recycling

- The inspection, installation, hydraulic connection and

commissioning of the device must be carried out by qual-

ified skilled personnel only in compliance with the current

regulations.

- Electric and hydraulic connections and their correct func-

tioning are the responsibility of the installer.

- Do not change any control or safety elements without pri-

or approval by the manufacturer or the local sales office.

- Improper use caused by ignoring the instructions given in

this manual

- Non-observance of the operating conditions of the device.
- Installation and maintenance by personnel without proper

qualification.

- Improper use of the device or operation under conditions

not conforming to the manual.

- Use of spare parts that are not original spare parts.

It is recommended recycling the components of

the device

at the end of the device service life as completely

as possible 

or use them for a different purpose.

Components that cannot be recycled must be

properly disposed of by an authorized disposal

company in accordance with current legal regula-

tions.

It is recommended keeping this manual at a safe lo-

cation after installation and use it for future mainte-

nance activities.

Hazard warning

Important information

Safety information

Recycling

Summary of Contents for DISA-W

Page 1: ...Ferdinand Schad KG Steigstra e 25 27 D 78600 Kolbingen Telephone 49 0 74 63 980 0 Fax 49 0 74 63 980 200 info schako de www schako de Installation Mounting and Maintenance DISA W...

Page 2: ...livered model 4 Function 4 Installation and commissioning 5 Operating conditions 5 Material reception 5 Transport lifting and handling 5 Storage 5 Installation 6 Mounting 6 Hydraulic connections 7 Con...

Page 3: ...acement of defec tive materials Recycling The inspection installation hydraulic connection and commissioning of the device must be carried out by qual ified skilled personnel only in compliance with t...

Page 4: ...iffus er system and a steel frame Grille 3 Possible designs perforated sheet grille made of gal vanised sheet steel perforated sheet grille models SR SQ RE and OB made of extruded aluminium profile PA...

Page 5: ...ns Coolant or heating fluid water or glycols ethylene or pro pylene at a concentration below 60 Water inlet temperature above the dew point up to 80 C Please note that some connectors do not work at w...

Page 6: ...rews and can be fastened to the load bearing ceiling using threaded bars provided on site or other fastening material approved by the building supervisory authorities Make sure that places that are in...

Page 7: ...hydraulic circuit If the unit is to be installed at a location having temperatures be low zero degrees glycol must be admixed to the coolant in a suitable ratio to ensure that the freezing point of th...

Page 8: ...ors etc in places with draught air or directly opposite to an air diffuser grille Temperature controls must be mounted at least 1 5 me tres above the floor Mounting temperature controls on walls towar...

Page 9: ...ommended wearing personal protective equip ment in order to avoid cuts and other injuries produced by sharp and pointed parts To avoid accidental rotation or folding down of the grille please check t...

Page 10: ...n the meter and the following formula can be used to to determine the volumetric flow V l s Primary air flow Ps Pa Static pressure The K value is taken from the following table Air density 1 2 kg m3 N...

Page 11: ...ic system Ventilation of the hydraulic system Please inform the installer Installed unfavourable or malfunctions at the temperature control or sensor Install thermostat in a different place Clogging o...

Page 12: ...Installation Mounting and Maintenance DISA W Z11 27 12 Construction subject to change No return possible 20 10 2015 Version...

Reviews: