background image

page 4 

 

version 1.2_en 

Calibration curves 

name 

paper type 

density 

600 paper 

Very low density paper 

600 kg/m³

 

650 paper 

Low density paper 

650 kg/m³

 

700 paper 

Low density paper 

700 kg/m³

 

750 paper 

Fluting, Schrenz 

750 kg/m³

 

800 paper 

Newsprint paper 

800 kg/m³

 

850 paper 

Kraftliner brown 

850 kg/m³

 

900 paper 

Kraftliner White Top, Testliner brown 

900 kg/m³

 

950 paper 

Testliner white, copy paper 

950 kg/m³

 

1000 paper 

Copy paper, LWC raw 

1000 kg/m³

 

1050 paper 

Copy paper calendered 

1050 kg/m³

 

1100 paper 

Copy paper calendered 

1100 kg/m³ 

1200 paper 

LWC calendered 

1200 kg/m³ 

1300 paper 

Flysheet paper 

1300 kg/m³ 

1400 paper 

Flysheet paper 

1400 kg/m³ 

1500 paper 

Flysheet paper high density 

1500 kg/m³ 

1600 paper 

Flysheet paper very high density 

1600 kg/m³ 

Empty 1700 

For creation of customer calibration curve 

 

Empty 975 

For creation of customer calibration curve 

 

Empty 550 

For creation of customer calibration curve 

 

reference 

 

! Only for checking the instrument ! 

 

 

List of calibration curves 

By  pressing  one  of  the  arrow  keys  in  the 
measuring window for approx. 3 seconds a list 
of  all  available  calibration  curves  opens.  Now 
you  can  select  your  desired  curve  using  the 
arrow  keys  and  confirm  by  pressing 

.

Summary of Contents for humimeter PM3

Page 1: ...User manual humimeter PM3 paper moisture meter version 1 2_en Schaller GmbH 2012 ...

Page 2: ...nning rolls the PM4 contact free temperature measurement is necessary 4 Now the display shows the water content The temperature is shown on the left 5 To save the results in the save menu press the button The storage was successful when the number in front of the symbol increased To reach the store menu please press the left button 6 The menu level Options Log time offers the possibility to activa...

Page 3: ...es that offer realistic results and write down the measuring results of the different calibration curves 2 Now please note the effective water content determined by your online measurement system or carry out a reference measurement according to EN ISO 287 3 Compare the determined reference water content with the measuring results of the different calibration curves Use the calibration curve with ...

Page 4: ... Copy paper calendered 1100 kg m 1200 paper LWC calendered 1200 kg m 1300 paper Flysheet paper 1300 kg m 1400 paper Flysheet paper 1400 kg m 1500 paper Flysheet paper high density 1500 kg m 1600 paper Flysheet paper very high density 1600 kg m Empty 1700 For creation of customer calibration curve Empty 975 For creation of customer calibration curve Empty 550 For creation of customer calibration cu...

Page 5: ...with a dry cloth For cleaning the steel clamps you can also use alcohol Please do not deform the steel clamps If the device is not used for a longer period 2 months or when the batteries are empty they should be removed to prevent a leakage of the battery acid name of calibration curve rolling menu button protective rubber housing removable ON OFF button measuring value water content measuring val...

Page 6: ...tch upper Switch lower Save Hold Watch saved data Add supplier s data menu Enter Switch upper Switch lower Back Enter numbers Enter letters Next or right Left Yes No Shift OK Menu level overview Data storage Manual logs Auto logs Clear logs Print logs Last logs All logs Clear logs Send logs Manual logs Auto logs Clear logs Options Options Date Time Log Time Language Unlock C F Calibrate o Userleve...

Page 7: ...menu item Options using the arrow keys Confirm by pressing the button Select the menu item Calibrate using the arrow keys and confirm by pressing This menu item has to be unlocked For that you have to enter the 4 digit serial number of your humimeter PM3 You can find the serial number on the top right edge of the display a short time after switching on the instrument or on the sticker in the batte...

Page 8: ...after switching on the batteries have to be changed IMMEDIATELY Also remove the batteries if you do not use your humimeter device for a longer period For eventual resulting damages we cannot provide any warranty Exemption from liability For miss readings and wrong measurements and of this resulting damage we refuse any liability This is a device for quick determination of moisture The moisture dep...

Page 9: ...e data transfer on the humimeter Press the key until you reach the menu see image on the right Then select Send Logs and confirm by pressing the key Now select Manual Logs and confirm by pressing again All saved logs will be sent to your PC Starting the data transfer on your PC Press the button remote control in the LogMemorizer software A drop down menu with several options opens see image below ...

Page 10: ...M3 Then switch on the device Not till then the other side of the cable has to be plugged in at the printer Switch on the printer by pressing Now the green LED is blinking If it does not blink please change the batteries and try again Press the button at your humimeter until you reach the menu see image on the right Select Print Logs and confirm by pressing Now you can select if you want to print t...

Page 11: ...x 10 000 values Menu languages German English French Italian Spanish Russian Power supply 4 pcs 1 5 Volt AA Alkaline batteries for approx 900 measurements Switch off time after approx 4 minutes Power consumption 60 mA with display lighting Display 128 x 64 matrix display with LED backlighting Dimensions 182 x 75 x 54 mm with rubber housing Weight 330g incl batteries and rubber housing Protection c...

Page 12: ...of application range The application range is between 0 and 60 C Discrepancy in temperature between device and material Please ensure that the device and the material under test are being stored at nearly the same temperature before measuring A high temperature difference has a negative effect on the stability of the measurement results Measurement at the front side A measurement at the front side...

Reviews: