Operating Instruction Manual

  

Elektroblock EBL 263-5  Art no 911.056

 

 

page 6 

/

 10

 

Note: this operating instruction manual is intended for the customer and has to be supplied with the device 

 

Schaudt GmbH, Elektrotechnik & Apparatebau, Daimlerstraße 5, D-88677 Markdorf, Tel +49 7544 9577-0, Fax +49 7544 9577-29, www.schaudt-gmbh.de  18.05.2004

 

12V fuses 

The Elektroblock is equipped with so called PolySwitch fuses. 
In case of failure, eg overload, such fuses break the relevant circuit, thus 
protecting the device. PolySwitch fuses automatically reset themselves 
after the fault has been removed. In case of failure the corresponding LED 
lights and indicates the faulty circuit. 

The electrical circuits are from left to right: 

 

refrigerator  

15  A 

waste water heater/ 
water pump 

10 A 

light circuit 3 

10 A 

light circuit 2 

10 A 

light circuit 1 

10 A 

automatic step 

15 A 

*  In some cases of short circuit, the main fuse of the starter or the living-area battery might blow instead 

of the respective PolySwitch fuse. In this instance please disconnect the mains supply of the motor 
home and take off all battery terminals of the positive poles. After that insert a new main fuse of the 
same value. Before power is put back on, it is advisable to rectify the reason for the short circuit. 
Please see section 5 'Electrical Installation' and in enclosure 'Schematic Diagram'. 

*  Troubleshooting hints when main fuses are blown (qualified personnel only): 

• 

A minimum of two main fuses are required; for the value refer to schematic diagram. 

• 

Undo the four screws at each corner of the front panel and pull out the device. 

• 

Disconnect all positive poles of each of the seven consumer circuits, label each one well. 

• 

Insert a new main fuse. Caution, danger of burning. Better disconnect the positive battery 

terminal first. If the fuse blows again, the main circuit of the battery is at fault, otherwise: 

• 

Actuate 12V-switch on front panel of EBL 263-5: the green LED must light.  

• 

Connect one consumer circuit after the other by reconnecting the appropriate positive poles. 

Wait for at least 10sec after each connection is made and observe the green LED.  

• 

The consumer circuit with the green LED going off is at fault. 

• 

Disconnect the appropriate positive pole of the faulty circuit and rubber-tape it against accidental 

contact. 

• 

Insert a new main fuse and reconnect all other remaining consumer circuits. 

• 

All other circuits should function now. The faulty circuit should be repaired without delay.  

 

 

CAUTION !

 

Danger of burning. Change defective fuses only at zero-current. 

 

3.3 Relay 

Functions 

main-switch relay  

This relay is controlled by the push-button switch 

12V

 on front panel. 

bistable 

It switches all 12V load off, except the circuit 'automatic step'. 
See section 3.1 'Controls and Indicators'. 

battery cut-off relay 

This relay separates the starter and living-area battery when the engine 
is not running and if there is no voltage on terminal 'D+'. 
Both batteries are connected in parallel and therefore simultaneously 
charged while engine is running. 

water pump relay 

This relay activates the water pump and is controlled by the 'water pump' 
switch on the front panel. In 'ON' position the 'water pump' output is active. 
See section 3.1 'Controls and Indicators' 
Battery drain of relay: 160mA in 'ON' position 

Summary of Contents for 911.056

Page 1: ...ol the living area functions of the motor home and indicate certain values like voltages or filling levels Tank sensors are necessary to measure the filling levels of the water tanks Please do order separately Note The EBL 263 5 is not suitable for filling level measurement of metal water tanks 1 1 Suitable Accessories rod tank sensors 2 rod tank sensors 2 sensor cables 4 x 0 5 2 seal rings art no...

Page 2: ...charge at constant 14 4V selectable 20 minutes duration for lead acid 6h duration for lead gel batteries U then automatic change over to float charge at 13 8V If due to high loads the float voltage of 13 8V cannot be provided the battery charger switches over from float to boost charge safety circuits short circuit and reverse polarity protected charger needs a connected battery with a voltage of ...

Page 3: ...d must be conform to specifications mentioned in this operating instruction manual see instruction manual section 4 2 Installation section 5 Electrical Installation and in enclosure schematic diagram of EBL 263 5 In the following text special notice should be paid to the signs shown below Caution Electrical current hazard warning Caution General hazard warning 3 Operating Instructions 3 1 Controls...

Page 4: ... hours Low charging current or 12V system overloaded green 12 3V Battery properly charged Standard charge Standard charge Low voltage warning indicator Optical warning of a alarming low living area battery charge As soon as the living area battery voltage drops below 10 8V the red warning light starts blinking Any load must now be switched off immediately and the living area battery should be rech...

Page 5: ...s shown Actuate switch in direction of Filling level of waste water tank is shown LED with symbol is on water tank full LED with symbol is on water tank approx half full LED with symbol is on water tank approx a quarter full No LED indication water tank empty Note Inquiry of water tank filling levels is for temporary use only The used method of measurement is not suitable for continuous operation ...

Page 6: ...ws at each corner of the front panel and pull out the device Disconnect all positive poles of each of the seven consumer circuits label each one well Insert a new main fuse Caution danger of burning Better disconnect the positive battery terminal first If the fuse blows again the main circuit of the battery is at fault otherwise Actuate 12V switch on front panel of EBL 263 5 the green LED must lig...

Page 7: ...rt period of time However the 12 V system cannot be switched on if the battery voltage stays under 11 0V In any case the living area battery should be fully recharged as soon as possible 4 Transport Storage Installation 4 1 Transport Storage The EBL should be stored and transported in a suitable packing and in a dry environment only Storage temperature range 20 C to 70 C 4 2 Installation The EBL h...

Page 8: ...act junction box The device must be used exclusively in vehicles equipped with an easily accessible cut out eg a circuit breaker in the wardrobe 5 2 Batteries and D Alternator The battery is connected by a 3 pole EURO terminal The alternator control signal D is connected to terminal 6 of the 6 pole plug in screw terminal water tank 2 waste water Cable size dimensions have to be in accordance with ...

Page 9: ...type selector switch See section 3 1 Controls 6 2 Shut Down Before and after shut down eg winter recess the battery should be fully recharged Connect the motor home to mains supply and charge the battery for a minimum of 16 hours 80Ah battery or 24 hours 160Ah battery Before long periods of disuse the motor home battery should be disconnected from the 12V system Take off terminals at battery poles...

Page 10: ...ore not liable to resulting damages 8 Enclosure To this operating instruction manual belongs the enclosed schematic diagram the table of measurement and front and back view drawings of the Elektroblock EBL 263 5 art no 911 056 This operating instruction manual with all its enclosures must be delivered together with the energy management system Elektroblock EBL 263 5 art no 911 056 It has to be par...

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ......

Reviews: